Labotemp CO₂ Incubator LCI-103 offers a 160 L chamber for controlled cell culture and biological research. Available with air-jacketed or water-jacketed heating, this CO₂ incubator for cell culture supports laboratories working in cell biology, oncology, genetics, immunology, virology, and pharmaceutical research. Microprocessor-based touchscreen control simplifies operation, while a temperature range of ambient +5°C to 65°C and accuracy of ±0.1°C help maintain stable culture conditions. NDIR technology provides adjustable CO₂ control from 0–20%, supporting a range of laboratory incubation requirements.
The LCI-103 features a corrosion-resistant stainless-steel chamber, double-door design with a tempered-glass viewing door, and independent door heating to help reduce condensation. Natural evaporation humidification maintains relative humidity above 95% under specified stable operating conditions at 37°C. UV disinfection helps reduce contamination risks, while an optional HEPA filtration system provides additional particle filtration. With three standard carrier brackets, rapid temperature and CO₂ recovery after door opening, and a choice of heating systems, the 160 L incubator supports practical, consistent cell culture workflows.
Why Choose Labotemp CO₂ Incubator For Cell Culture LCI-103?
✓Stable Environmental Control: ±0.1°C temperature accuracy and adjustable NDIR CO₂ control.
✓Contamination Management: UV disinfection and optional HEPA filtration.
✓160 L Working Capacity: Supports larger cell culture batches.
| General Specifications | |
|
Product Type : CO₂ Incubator Product Type |
CO₂ Incubator |
|
Capacity : 160 L Capacity |
160 L |
|
Heating Method : Air-jacketed / Water-jacketed Heating Method |
Air-jacketed / Water-jacketed |
|
Standard Carrier Brackets : 3 pcs Standard Carrier Brackets |
3 pcs |
| Temperature Control | |
|
Temperature Range : Ambient +5°C to 65°C Temperature Range |
Ambient +5°C to 65°C |
|
Temperature Accuracy : ±0.1°C Temperature Accuracy |
±0.1°C |
|
Temperature Recovery Time : ≤8 min to recover to 37°C after a 30-second door opening Temperature Recovery Time |
≤8 min to recover to 37°C after a 30-second door opening |
|
Ambient Temperature : RT +5°C to 30°C Ambient Temperature |
RT +5°C to 30°C |
| CO₂ Control | |
|
CO₂ Control Technology : NDIR CO₂ Control Technology |
NDIR |
|
CO₂ Control Range : 0–20% CO₂ Control Range |
0–20% |
|
CO₂ Recovery Time : ≤3 min to recover to 5% after a 30-second door opening CO₂ Recovery Time |
≤3 min to recover to 5% after a 30-second door opening |
| Humidity and Disinfection | |
|
Humidification Method : Natural evaporation Humidification Method |
Natural evaporation |
|
Relative Humidity : >95% RH at stable operation at 37°C Relative Humidity |
>95% RH at stable operation at 37°C |
|
Disinfection Method : UV disinfection Disinfection Method |
UV disinfection |
| Timer and Operation | |
|
Timer Range : 0–999 h 59 min or continuous Timer Range |
0–999 h 59 min or continuous |
|
Control System : Microprocessor-based touchscreen control Control System |
Microprocessor-based touchscreen control |
|
Viewing Door : Tempered-glass inner viewing door Viewing Door |
Tempered-glass inner viewing door |
|
Door Heating : Independent door heating Door Heating |
Independent door heating |
| Chamber Dimensions and Construction | |
|
Inner Chamber Dimensions (W × D × H) : 500 × 500 × 650 mm Inner Chamber Dimensions (W × D × H) |
500 × 500 × 650 mm |
|
Outer Dimensions (W × D × H) : 650 × 690 × 1045 mm Outer Dimensions (W × D × H) |
650 × 690 × 1045 mm |
|
Chamber Material : Stainless steel Chamber Material |
Stainless steel |
| Electrical Specifications | |
|
Power : 900 W / 1000 W Power |
900 W / 1000 W |
|
Standard Power Supply : AC 220 V / 50 Hz ; AC 110 V / 60 Hz Standard Power Supply |
AC 220 V / 50 Hz ; AC 110 V / 60 Hz |