Labotemp Cryostat Microtome CRM-02 is a high-performance microtome machine designed for precise cryostat sectioning and microtomy in histopathology. Also referred to as a freezing microtome or cryotome, this cryostat microtome enables reliable frozen tissue sectioning for intraoperative diagnosis and urgent pathology workflows. The RD-2280 delivers consistent thin sections with an adjustable cut thickness from 0.5 µm to 100 µm, supporting accurate microtomy and dependable sample preparation.
The fully enclosed cryogenic chamber operates from 0°C to –60°C, ensuring stable freezing conditions for reproducible results. Precise specimen control with 65 mm vertical stroke, 22 mm horizontal stroke, and up to 100 µm specimen retraction improves section quality and protects the blade. A rigid microtome blade holder supports standard disposable blades and knives, maintaining a stable cutting edge for clean, repeatable sections.
Why choose Labotemp Cryostat Microtome CRM-02?
✓Wide sectioning range: Accurate frozen sections from 0.5–100 µm
✓Stable freezing control: Reliable operation down to –60°C
✓Laboratory safety: Enclosed chamber with UV disinfection
|
Section thickness range :
0.5 µm to 100 µm adjustable |
0.5 µm to 100 µm adjustable 0.5 µm to 5 µm in 0.5 µm increment 5 µm to 20 µm in 1 µm increment 20 µm to 40 µm in 2 µm increment 40 µm to 100 µm in 5 µm increment |
|
Trimming thickness range :
10 µm to 600 µm adjustable |
10 µm to 600 µm adjustable 10 µm to 50 µm, in 5 µm increment 50 µm to 100 µm, in 10 µm increment 100 µm to 600 µm, in 50 µm increment |
|
Tissue retraction function : 0–100 µm adjustable in 5 µm increment Tissue retraction function |
0–100 µm adjustable in 5 µm increment |
|
Pellet cooling working time : 15 minutes Pellet cooling working time |
15 minutes |
|
Freezing chamber temperature range : 10 °C to −50 °C Freezing chamber temperature range |
10 °C to −50 °C |
|
Speed of fast forward / backward : 0.9 m/s, 0.45 m/s Speed of fast forward / backward |
0.9 m/s, 0.45 m/s |
|
Specimen head minimum temperature : 10 °C to −50 °C Specimen head minimum temperature |
10 °C to −50 °C |
|
Maximum specimen size : 55×80 mm Maximum specimen size |
55×80 mm |
|
Freeze shelf minimum temperature : −50 °C Freeze shelf minimum temperature |
−50 °C |
|
Specimen vertical stroke : 65 mm Specimen vertical stroke |
65 mm |
|
Lowest temperature of Peltier units on freezing shelf : −60 °C Lowest temperature of Peltier units on freezing shelf |
−60 °C |
|
Specimen horizontal stroke : 22 mm Specimen horizontal stroke |
22 mm |
|
Voltage and frequency : AC 220 V / 50 Hz Voltage and frequency |
AC 220 V / 50 Hz |
|
QTY of Peltier : 8 pcs QTY of Peltier |
8 pcs |
|
Dimensions (W × D × H) : 700×760×1160 mm Dimensions (W × D × H) |
700×760×1160 mm |
|
Disinfection method : UV Disinfection method |
UV |
|
Net Weight : 210 kg Net Weight |
210 kg |
|
Gross Weight : 225 kg Gross Weight |
225 kg |
Touchscreen Control
➤ Touchscreen ControlLarge-area quick freezing shelf for preparing multiple specimens
➤ Large-area quick freezing shelf for preparing multiple specimensSpecimen retraction function to prevent section damage
➤ Specimen retraction function to prevent section damageHigh-brightness cold LED illumination
➤ High-brightness cold LED illuminationUV sterilization for chamber disinfection
➤ UV sterilization for chamber disinfectionFully enclosed freezing chamber for stable cooling
➤ Fully enclosed freezing chamber for stable cooling16-position hand wheel for operational safety
➤ 16-position hand wheel for operational safetyEquipped with Danfoss (Secop) brand compressor
➤ Equipped with Danfoss (Secop) brand compressorCRM-02 is used for rapid frozen sectioning in hospitals, pathology laboratories, surgical departments, oncology units, and research laboratories for fast and accurate tissue diagnosis
➤ CRM-02 is used for rapid frozen sectioning in hospitals, pathology laboratories, surgical departments, oncology units, and research laboratories for fast and accurate tissue diagnosis
CRM-02 is used for rapid frozen sectioning in hospitals, pathology laboratories, surgical departments, oncology units, and research laboratories for fast and accurate tissue diagnosis.