ISO & CE Certified • Global Supply Chain • Comprehensive Warranty
WhatsApp Us!
Request Quote!
0

Biosafety Cabinet Class 2 Type B2 LBS-301

A4 preview · Your PDF uses these same pages.

Biosafety Cabinet Class 2 Type B2 LBS-301
Get to know

Why choose
Biosafety Cabinet Class 2 Type B2 LBS-301?

  1. 1
    100% Air Exhaust
  2. 2
    Dual H14 HEPA filters provide ≥99.995% filtration efficiency at 0.3 μm.
  3. 3
    Negative-pressure work area helps prevent contaminated air leakage from the cabinet.
LBS-301

Biosafety Cabinet Class II

Biosafety Cabinet Class 2 Type B2 LBS-301
Biosafety Cabinet Class 2 Type B2 LBS-301
Overview

Product
Description

Product overview

Biosafety Cabinet Class 2 Type B2 LBS-301

Labotemp Biosafety Cabinet Class 2 Type B2 LBS-301 is a high-performance biological safety hood class 2 designed to provide protection for operators, samples, and the laboratory environment during biological and other hazardous laboratory procedures. It features a 100% air exhaust system, with contaminated air passing through HEPA filtration before being exhausted externally, while the work area operates under negative pressure. This configuration is suitable for biological safety laboratories and applications involving appropriate volatile chemicals and radioactive nuclides.

The cabinet provides a 610 × 550 × 600 mm working area with a motorized toughened-glass front window, 304 stainless steel removable work surface, and dual H14 HEPA filters with ≥99.995% efficiency at 0.3 μm. A 7-inch LCD touchscreen provides real-time monitoring of airflow, front-window status, temperature, filter and UV lamp life, and system status. The LBS-301 also incorporates an air velocity sensor, UV sterilization with timer, audio-visual alarms, safety interlocks, power-failure memory, and a standard exhaust blower with 9 m exhaust duct. These integrated functions support convenient operation, monitoring, cleaning, and routine laboratory workflows.

Why Choose Labotemp Biosafety Cabinet Class 2 Type B2?

✓ Effective Filtration: Dual H14 HEPA filters provide ≥99.995% filtration efficiency at 0.3 μm.
✓ Advanced Monitoring: 7-inch LCD touchscreen and air velocity sensor support real-time system monitoring.
✓ Complete Exhaust System: Standard exhaust blower and 9 m exhaust duct support external air discharge.

Technical data · LBS-301

Complete Specifications

Biosafety Cabinet Class 2 Type B2 LBS-301
No.SpecificationValue
Cabinet Specifications
1Product TypeClass II Type B2 Biological Safety Cabinet
2Internal Size (W×D×H)610 × 550 × 600 mm
3External Size (W×D×H)710 × 760 × 2050 mm
4Maximum Opening370 mm
5Work Surface Height750 mm
6Main BodyElectro-galvanized steel with antimicrobial powder coating
7Work Surface304 stainless steel
8Front WindowMotorized, toughened glass
9Side WindowIncluded as standard
Airflow & Filtration
10Airflow Mode100% Air Exhaust
11Downflow Velocity0.35 ± 0.025 m/s
12Inflow Velocity0.52 ± 0.025 m/s
13Inflow Air Volume240 m³/h (141 CFM)
14Downflow Air Volume560 m³/h (330 CFM)
15Exhaust Air Volume800 m³/h (471 CFM)
16HEPA Filter2 pcs H14 HEPA filters, ≥99.995% efficiency at 0.3 μm
17Cleanliness GradeClass 100 (ISO 14644.1 Class 5)
Control & Safety
18Display7-inch LCD Touch Screen
19AlarmAbnormal airflow velocity, HEPA filter failure, UV lamp failure, front window at unsafe height
20UV Lamp15 W × 1, 253.7 nm, UV life indicator and UV timer
21LED Lamp10 W × 2
22Illumination≥900 Lux
23Safety InterlockUV lamp/front window; UV lamp/blower/LED lamp; blower/front window
24Power-Failure MemoryIncluded
25Air Velocity MonitoringAir velocity sensor with real-time monitoring and display
26Exhaust SystemExhaust blower with 9 m exhaust duct, Φ305 mm
Electrical & Physical Specifications
27Maximum Consumption350 W, excluding socket consumption
28Power SupplyAC 220 V ±10%, 50/60 Hz; 110 V ±10%, 60 Hz
29Sound Emission≤65 dB(A)
30Vibration of Work Surface≤2 μm
31Net Weight140 kg (Main Unit); 65 kg (Exhaust Blower)
32Gross Weight175 kg (Main Unit); 80 kg (Exhaust Blower)
33Shipping Size – Main Unit (W×D×H)850 × 990 × 1640 mm
34Shipping Size – Exhaust Blower730 × 660 × 500 mm
35Shipping Volume1.62 m³
What's included

Features

  1. 1
    100% Air Exhaust
  2. 2
    Dual H14 HEPA filters provide ≥99.995% filtration efficiency at 0.3 μm.
  3. 3
    Negative-pressure work area helps prevent contaminated air leakage from the cabinet.
  4. 4
    7-inch LCD touchscreen provides real-time monitoring of front window status, airflow velocity, temperature, filter and UV lamp life, and system status.
  5. 5
    Air velocity sensor enables real-time airflow monitoring and precise control.
  6. 6
    Motorized front window provides convenient adjustment with control and travel limit protection.
  7. 7
    UV sterilization function with programmable timing supports routine cabinet decontamination.
  8. 8
    Automatic safety interlocks coordinate the UV lamp, blower, LED lamp, and front window.
  9. 9
    100% air exhaust system eliminates internal air recirculation and supports external exhaust of cabinet air.
  10. 10
    Audio-visual alarms indicate abnormal airflow velocity, HEPA filter failure, UV lamp failure, and unsafe front-window height.
  11. 11
    Power-failure memory retains operating information after power interruption.
  12. 12
    Standard foot switch allows convenient up-and-down adjustment of the motorized front window.
  13. 13
    Removable 304 stainless steel work surface facilitates cleaning and disinfection.
  14. 14
    Dish-type work surface with stainless steel liquid collecting tank helps prevent liquid leakage and simplifies cleaning.
  15. 15
    Perforations on all four sides support more uniform airflow within the work area.
  16. 16
    Exhaust blower and 9 m exhaust duct are provided as standard for the external exhaust system.
  17. 17
    Unibody front-panel design provides improved sealing compared with a spliced front-panel construction.
  18. 18
    Optional upgraded LED lighting provides RG0 blue-light protection, anti-glare eye protection, and high color rendering.
  19. 19
    Optional gas tap, water tap, pressure sensor, IV bar with hooks, ULPA filter, and DC blower allow configuration according to laboratory requirements.
Where it's used

Applications

Biological Safety Laboratories: Suitable for laboratory procedures requiring protection of operators, samples, and the surrounding environment from biological hazards.

Microbiology Laboratories: Used for handling and processing biological samples where controlled airflow and containment are required.

Research & Development Laboratories: Supports biological research workflows involving potentially hazardous or unknown biological materials.

Pharmaceutical Laboratories: Suitable for controlled laboratory processes involving biological materials and contamination-sensitive procedures.

Biotechnology Laboratories: Used for biological experiments and sample handling requiring Class II containment.

Clinical & Diagnostic Laboratories: Supports the handling and processing of biological specimens under controlled laboratory conditions.

Laboratories Using Volatile Chemicals: The 100% external exhaust configuration makes the cabinet suitable for applications where biological procedures involve appropriate volatile chemical hazards.

Radioisotope-Related Biological Work: Suitable for certain biological procedures involving radioactive nuclides where total external exhaust is required.

Biosafety Cabinet Class 2 Type B2 LBS-301

LET'S EQUIP
YOUR LABORATORY

View product online

+1 581 465 8405

www.labotemp.com · info@labotemp.com

144 E, Midwest Avenue, Casper WY 82601, USA

More about this product

Standard Accessories

  1. 1
    Side Window
  2. 2
    Gas Tap
  3. 3
    Water Tap
  4. 4
    Pressure Sensor
  5. 5
    IV Bar With Hooks
  6. 6
    ULPA Filter
  7. 7
    Upgraded LED Lamp
  8. 8
    DC Blower
More about this product

Optional Accessories

  1. 1
    Side Window
  2. 2
    Base Stand
  3. 3
    Air Velocity Sensor
  4. 4
    LCD Touch Screen
  5. 5
    LED Lamp ×2
  6. 6
    UV Lamp ×1
  7. 7
    Explosion-Proof/Waterproof Socket ×1
  8. 8
    Motorized Front Window
  9. 9
    Footmaster Caster
  10. 10
    Foot Switch
  11. 11
    Removable Shallow-Plate Stainless Steel Work Surface
  12. 12
    Exhaust Blower
  13. 13
    9 m Exhaust Duct (Φ305 mm)
  14. 14
    Magnetic File Folder
More about this product

Optional Modules

No.Rotor / AdapterMax CapacityMax SpeedMax RCFTube Type
1Angle Rotor + Adapter12 × 5–10–15 ml; Adapter: 12 × 2 ml6000 r/min6080 × gPP / PC tube
2Swing Rotor (Steel frame)4 × 100 ml / 4 × 50 ml; Adapter: 4 × 15/10 ml5000 r/min4752 × gPP / PC tube
3Swing Rotor + Adapter + Rack4 × 2 × 100 ml / 4 × 2 × 50 ml; Adapter: 4 × 2 × 15/10 ml; Rack: 4 × 12 × 5/2 ml4000 r/min3041 × gPP/PC tube / Vacuum blood collection tube
4Swing Bucket72 × 2–5 ml4000 r/min2773 × gVacuum blood collection tube
5Swing Bucket + Adapters4 × 400 ml; Adapter: 4 × 16 × 5/2 ml / 4 × 9 × 15/10 ml / 4 × 4 × 50 ml / 4 × 1 × 100 ml4000 r/min3049 × gPP / PC tube / Vacuum blood collection tubes
6Swing Bucket + Adapters4 × 250 ml; Adapter: 4 × 9 × 5/2 ml / 4 × 5 × 15/10 ml / 4 × 1 × 50 ml / 4 × 1 × 100 ml / 4 × 9 × 1.5 ml4000 r/min3049 × gPP / PC tube
7Microplate Rotor + Adapter2 × 2 × 96 well; Adapter: 2 × 32 × 1.5 ml4200 r/min3057 × gSquare cup / PP-PC tube
More about this product

Adapter Selection

ProgramSpeedCentrifuge Time
CGF2600 rpm2 min
A-PRF2300 rpm4 min
I-PRF2600 rpm4 min
   
More about this product

Spare Accessories

  1. 1
    UV light
  2. 2
    Stand
  3. 3
    Consumables