Labotemp Biosafety Cabinet Class 2 Type B2 LBS-301 is a high-performance biological safety hood class 2 designed to provide protection for operators, samples, and the laboratory environment during biological and other hazardous laboratory procedures. It features a 100% air exhaust system, with contaminated air passing through HEPA filtration before being exhausted externally, while the work area operates under negative pressure. This configuration is suitable for biological safety laboratories and applications involving appropriate volatile chemicals and radioactive nuclides.

The cabinet provides a 610 × 550 × 600 mm working area with a motorized toughened-glass front window, 304 stainless steel removable work surface, and dual H14 HEPA filters with ≥99.995% efficiency at 0.3 μm. A 7-inch LCD touchscreen provides real-time monitoring of airflow, front-window status, temperature, filter and UV lamp life, and system status. The LBS-301 also incorporates an air velocity sensor, UV sterilization with timer, audio-visual alarms, safety interlocks, power-failure memory, and a standard exhaust blower with 9 m exhaust duct. These integrated functions support convenient operation, monitoring, cleaning, and routine laboratory workflows.

Why Choose Labotemp Biosafety Cabinet Class 2 Type B2?

✓ Effective Filtration: Dual H14 HEPA filters provide ≥99.995% filtration efficiency at 0.3 μm.
✓ Advanced Monitoring: 7-inch LCD touchscreen and air velocity sensor support real-time system monitoring.
✓ Complete Exhaust System: Standard exhaust blower and 9 m exhaust duct support external air discharge.

$5388
Datasheet

Specifications Biosafety Cabinet Class 2 Type B2 LBS-301

Cabinet Specifications

Product Type : Class II Type B2 Biological Safety Cabinet

Product Type
Class II Type B2 Biological Safety Cabinet

Internal Size (W×D×H) : 610 × 550 × 600 mm

Internal Size (W×D×H)
610 × 550 × 600 mm

External Size (W×D×H) : 710 × 760 × 2050 mm

External Size (W×D×H)
710 × 760 × 2050 mm

Maximum Opening : 370 mm

Maximum Opening
370 mm

Work Surface Height : 750 mm

Work Surface Height
750 mm

Main Body : Electro-galvanized steel with antimicrobial powder coating

Main Body
Electro-galvanized steel with antimicrobial powder coating

Work Surface : 304 stainless steel

Work Surface
304 stainless steel

Front Window : Motorized, toughened glass

Front Window
Motorized, toughened glass

Side Window : Included as standard

Side Window
Included as standard
Airflow & Filtration

Airflow Mode : 100% Air Exhaust

Airflow Mode
100% Air Exhaust

Downflow Velocity : 0.35 ± 0.025 m/s

Downflow Velocity
0.35 ± 0.025 m/s

Inflow Velocity : 0.52 ± 0.025 m/s

Inflow Velocity
0.52 ± 0.025 m/s

Inflow Air Volume : 240 m³/h (141 CFM)

Inflow Air Volume
240 m³/h (141 CFM)

Downflow Air Volume : 560 m³/h (330 CFM)

Downflow Air Volume
560 m³/h (330 CFM)

Exhaust Air Volume : 800 m³/h (471 CFM)

Exhaust Air Volume
800 m³/h (471 CFM)

HEPA Filter : 2 pcs H14 HEPA filters, ≥99.995% efficiency at 0.3 μm

HEPA Filter
2 pcs H14 HEPA filters, ≥99.995% efficiency at 0.3 μm

Cleanliness Grade : Class 100 (ISO 14644.1 Class 5)

Cleanliness Grade
Class 100 (ISO 14644.1 Class 5)
Control & Safety

Display : 7-inch LCD Touch Screen

Display
7-inch LCD Touch Screen

Alarm : Abnormal airflow velocity, HEPA filter failure, UV lamp failure, front window at unsafe height

Alarm
Abnormal airflow velocity, HEPA filter failure, UV lamp failure, front window at unsafe height

UV Lamp : 15 W × 1, 253.7 nm, UV life indicator and UV timer

UV Lamp
15 W × 1, 253.7 nm, UV life indicator and UV timer

LED Lamp : 10 W × 2

LED Lamp
10 W × 2

Illumination : ≥900 Lux

Illumination
≥900 Lux

Safety Interlock : UV lamp/front window; UV lamp/blower/LED lamp; blower/front window

Safety Interlock
UV lamp/front window; UV lamp/blower/LED lamp; blower/front window

Power-Failure Memory : Included

Power-Failure Memory
Included

Air Velocity Monitoring : Air velocity sensor with real-time monitoring and display

Air Velocity Monitoring
Air velocity sensor with real-time monitoring and display

Exhaust System : Exhaust blower with 9 m exhaust duct, Φ305 mm

Exhaust System
Exhaust blower with 9 m exhaust duct, Φ305 mm
Electrical & Physical Specifications

Maximum Consumption : 350 W, excluding socket consumption

Maximum Consumption
350 W, excluding socket consumption

Power Supply : AC 220 V ±10%, 50/60 Hz; 110 V ±10%, 60 Hz

Power Supply
AC 220 V ±10%, 50/60 Hz; 110 V ±10%, 60 Hz

Sound Emission : ≤65 dB(A)

Sound Emission
≤65 dB(A)

Vibration of Work Surface : ≤2 μm

Vibration of Work Surface
≤2 μm

Net Weight : 140 kg (Main Unit); 65 kg (Exhaust Blower)

Net Weight
140 kg (Main Unit); 65 kg (Exhaust Blower)

Gross Weight : 175 kg (Main Unit); 80 kg (Exhaust Blower)

Gross Weight
175 kg (Main Unit); 80 kg (Exhaust Blower)

Shipping Size – Main Unit (W×D×H) : 850 × 990 × 1640 mm

Shipping Size – Main Unit (W×D×H)
850 × 990 × 1640 mm

Shipping Size – Exhaust Blower : 730 × 660 × 500 mm

Shipping Size – Exhaust Blower
730 × 660 × 500 mm

Shipping Volume : 1.62 m³

Shipping Volume
1.62 m³

Features Biosafety Cabinet Class 2 Type B2 LBS-301

  • 100% Air Exhaust ➤ 100% Air Exhaust
  • Dual H14 HEPA filters provide ≥99.995% filtration efficiency at 0.3 μm. ➤ Dual H14 HEPA filters provide ≥99.995% filtration efficiency at 0.3 μm.
  • Negative-pressure work area helps prevent contaminated air leakage from the cabinet. ➤ Negative-pressure work area helps prevent contaminated air leakage from the cabinet.
  • 7-inch LCD touchscreen provides real-time monitoring of front window status, airflow velocity, temperature, filter and UV lamp life, and system status. ➤ 7-inch LCD touchscreen provides real-time monitoring of front window status, airflow velocity, temperature, filter and UV lamp life, and system status.
  • Air velocity sensor enables real-time airflow monitoring and precise control. ➤ Air velocity sensor enables real-time airflow monitoring and precise control.
  • Motorized front window provides convenient adjustment with control and travel limit protection. ➤ Motorized front window provides convenient adjustment with control and travel limit protection.
  • UV sterilization function with programmable timing supports routine cabinet decontamination. ➤ UV sterilization function with programmable timing supports routine cabinet decontamination.
  • Automatic safety interlocks coordinate the UV lamp, blower, LED lamp, and front window. ➤ Automatic safety interlocks coordinate the UV lamp, blower, LED lamp, and front window.
  • 100% air exhaust system eliminates internal air recirculation and supports external exhaust of cabinet air. ➤ 100% air exhaust system eliminates internal air recirculation and supports external exhaust of cabinet air.
  • Audio-visual alarms indicate abnormal airflow velocity, HEPA filter failure, UV lamp failure, and unsafe front-window height. ➤ Audio-visual alarms indicate abnormal airflow velocity, HEPA filter failure, UV lamp failure, and unsafe front-window height.
  • Power-failure memory retains operating information after power interruption. ➤ Power-failure memory retains operating information after power interruption.
  • Standard foot switch allows convenient up-and-down adjustment of the motorized front window. ➤ Standard foot switch allows convenient up-and-down adjustment of the motorized front window.
  • Removable 304 stainless steel work surface facilitates cleaning and disinfection. ➤ Removable 304 stainless steel work surface facilitates cleaning and disinfection.
  • Dish-type work surface with stainless steel liquid collecting tank helps prevent liquid leakage and simplifies cleaning. ➤ Dish-type work surface with stainless steel liquid collecting tank helps prevent liquid leakage and simplifies cleaning.
  • Perforations on all four sides support more uniform airflow within the work area. ➤ Perforations on all four sides support more uniform airflow within the work area.
  • Exhaust blower and 9 m exhaust duct are provided as standard for the external exhaust system. ➤ Exhaust blower and 9 m exhaust duct are provided as standard for the external exhaust system.
  • Unibody front-panel design provides improved sealing compared with a spliced front-panel construction. ➤ Unibody front-panel design provides improved sealing compared with a spliced front-panel construction.
  • Optional upgraded LED lighting provides RG0 blue-light protection, anti-glare eye protection, and high color rendering. ➤ Optional upgraded LED lighting provides RG0 blue-light protection, anti-glare eye protection, and high color rendering.
  • Optional gas tap, water tap, pressure sensor, IV bar with hooks, ULPA filter, and DC blower allow configuration according to laboratory requirements. ➤ Optional gas tap, water tap, pressure sensor, IV bar with hooks, ULPA filter, and DC blower allow configuration according to laboratory requirements.

Applications Biosafety Cabinet Class 2 Type B2 LBS-301

  • Biological Safety Laboratories: Suitable for laboratory procedures requiring protection of operators, samples, and the surrounding environment from biological hazards Biological Safety Laboratories
    Suitable for laboratory procedures requiring protection of operators, samples, and the surrounding environment from biological hazards
  • Microbiology Laboratories: Used for handling and processing biological samples where controlled airflow and containment are required Microbiology Laboratories
    Used for handling and processing biological samples where controlled airflow and containment are required
  • Research & Development Laboratories: Supports biological research workflows involving potentially hazardous or unknown biological materials Research & Development Laboratories
    Supports biological research workflows involving potentially hazardous or unknown biological materials
  • Pharmaceutical Laboratories: Suitable for controlled laboratory processes involving biological materials and contamination-sensitive procedures Pharmaceutical Laboratories
    Suitable for controlled laboratory processes involving biological materials and contamination-sensitive procedures
  • Biotechnology Laboratories: Used for biological experiments and sample handling requiring Class II containment Biotechnology Laboratories
    Used for biological experiments and sample handling requiring Class II containment
  • Clinical & Diagnostic Laboratories: Supports the handling and processing of biological specimens under controlled laboratory conditions Clinical & Diagnostic Laboratories
    Supports the handling and processing of biological specimens under controlled laboratory conditions
  • Laboratories Using Volatile Chemicals: The 100% external exhaust configuration makes the cabinet suitable for applications where biological procedures involve appropriate volatile chemical hazards Laboratories Using Volatile Chemicals
    The 100% external exhaust configuration makes the cabinet suitable for applications where biological procedures involve appropriate volatile chemical hazards
  • Radioisotope-Related Biological Work: Suitable for certain biological procedures involving radioactive nuclides where total external exhaust is required Radioisotope-Related Biological Work
    Suitable for certain biological procedures involving radioactive nuclides where total external exhaust is required

Standard Accessories

  • Side Window ➤ Side Window
  • Gas Tap ➤ Gas Tap
  • Water Tap ➤ Water Tap
  • Pressure Sensor ➤ Pressure Sensor
  • IV Bar With Hooks ➤ IV Bar With Hooks
  • ULPA Filter ➤ ULPA Filter
  • Upgraded LED Lamp ➤ Upgraded LED Lamp
  • DC Blower ➤ DC Blower

Optional Accessories

  • Side Window ➤ Side Window
  • Base Stand ➤ Base Stand
  • Air Velocity Sensor ➤ Air Velocity Sensor
  • LCD Touch Screen ➤ LCD Touch Screen
  • LED Lamp ×2 ➤ LED Lamp ×2
  • UV Lamp ×1 ➤ UV Lamp ×1
  • Explosion-Proof/Waterproof Socket ×1 ➤ Explosion-Proof/Waterproof Socket ×1
  • Motorized Front Window ➤ Motorized Front Window
  • Footmaster Caster ➤ Footmaster Caster
  • Foot Switch ➤ Foot Switch
  • Removable Shallow-Plate Stainless Steel Work Surface ➤ Removable Shallow-Plate Stainless Steel Work Surface
  • Exhaust Blower ➤ Exhaust Blower
  • 9 m Exhaust Duct (Φ305 mm) ➤ 9 m Exhaust Duct (Φ305 mm)
  • Magnetic File Folder ➤ Magnetic File Folder
No.Rotor / AdapterMax CapacityMax SpeedMax RCFTube Type
1Angle Rotor + Adapter12 × 5–10–15 ml; Adapter: 12 × 2 ml6000 r/min6080 × gPP / PC tube
2Swing Rotor (Steel frame)4 × 100 ml / 4 × 50 ml; Adapter: 4 × 15/10 ml5000 r/min4752 × gPP / PC tube
3Swing Rotor + Adapter + Rack4 × 2 × 100 ml / 4 × 2 × 50 ml; Adapter: 4 × 2 × 15/10 ml; Rack: 4 × 12 × 5/2 ml4000 r/min3041 × gPP/PC tube / Vacuum blood collection tube
4Swing Bucket72 × 2–5 ml4000 r/min2773 × gVacuum blood collection tube
5Swing Bucket + Adapters4 × 400 ml; Adapter: 4 × 16 × 5/2 ml / 4 × 9 × 15/10 ml / 4 × 4 × 50 ml / 4 × 1 × 100 ml4000 r/min3049 × gPP / PC tube / Vacuum blood collection tubes
6Swing Bucket + Adapters4 × 250 ml; Adapter: 4 × 9 × 5/2 ml / 4 × 5 × 15/10 ml / 4 × 1 × 50 ml / 4 × 1 × 100 ml / 4 × 9 × 1.5 ml4000 r/min3049 × gPP / PC tube
7Microplate Rotor + Adapter2 × 2 × 96 well; Adapter: 2 × 32 × 1.5 ml4200 r/min3057 × gSquare cup / PP-PC tube
ProgramSpeedCentrifuge Time
CGF2600 rpm2 min
A-PRF2300 rpm4 min
I-PRF2600 rpm4 min
   
  • UV light