ISO & CE Certified • Global Supply Chain • Comprehensive Warranty
WhatsApp Us!
Request Quote!
0

Hydrothermal Autoclave HRA-10

A4 preview · Your PDF uses these same pages.

Hydrothermal Autoclave HRA-10
Product Catalog

Hydrothermal Autoclave HRA-10

HRA-10

Get to know

Why choose
Hydrothermal Autoclave HRA-10?

  1. 1
    5 mL Compact Capacity
  2. 2
    316L stainless steel vessel provides strong construction and excellent corrosion resistance
  3. 3
    PPL liner provides reliable chemical containment for demanding reaction conditions
HRA-10

Hydrothermal Reactor Autoclave

Hydrothermal Autoclave HRA-10
Hydrothermal Autoclave HRA-10
Overview

Product
Description

Product overview

Hydrothermal Autoclave HRA-10

Labotemp Hydrothermal Reactor Autoclave HRA-10 provides a compact 5 mL reaction vessel for hydrothermal synthesis, high pressure digestion, sample pretreatment, and small scale chemical research. Designed for applications requiring elevated temperature and pressure, the reactor combines a corrosion resistant 316L stainless steel vessel with a PPL liner for reliable sample containment and resistance to demanding chemical conditions. Its compact 48 mm vessel diameter and 53 mm overall height make it suitable for small volume laboratory reactions where controlled conditions and efficient sample utilization are important.

The 5 mL configuration features a 27 mm inner vessel diameter, 42 mm liner height, and 6 mm liner thickness for secure sample containment. The screw tightened cover and gasket sealing arrangement support reliable operation during closed vessel reactions. The hydrothermal reactor series supports operation up to 250°C and 3.0 MPa when used within the specified operating conditions. Suitable applications include material synthesis, catalyst preparation, trace element analysis, chemical research, geological studies, environmental testing, and laboratory sample digestion.

Why Choose Labotemp Hydrothermal Reactor Autoclave HRA-10?

✓ Compact 5 mL Capacity: Designed for small scale reactions while minimizing sample and reagent requirements.
✓ 316L Stainless Steel Vessel: Provides strong construction and corrosion resistance for demanding laboratory applications.
✓ PPL Liner: Supplied with a PPL liner for reliable chemical containment and protection of the reaction vessel.

Technical data · HRA-10

Complete Specifications

Hydrothermal Autoclave HRA-10
No.SpecificationValue
Reactor & Operating Performance
1Capacity5 mL
2Maximum Temperature250 °C
3Maximum Pressure3.0 MPa
Vessel & Liner
4Vessel Material316L Stainless Steel
5Liner MaterialPPL
6Overall Height53 mm
7Vessel Height53 mm
8Vessel Diameter48 mm
9Vessel Inner Diameter27 mm
10Vessel Wall Thickness5.5 mm
11Liner Height42 mm
12Liner Thickness6 mm
13Liner Diameter27 mm
Construction & Dimensions
14Product Weight0.5 kg
What's included

Features

  1. 1
    5 mL Compact Capacity
  2. 2
    316L stainless steel vessel provides strong construction and excellent corrosion resistance
  3. 3
    PPL liner provides reliable chemical containment for demanding reaction conditions
  4. 4
    High temperature operation up to 250°C supports elevated temperature laboratory reactions
  5. 5
    High pressure operation up to 3.0 MPa enables controlled closed vessel reactions
  6. 6
    Secure gasket sealing system helps prevent leakage during high pressure operation
  7. 7
    Compact 48 mm vessel diameter allows convenient handling and efficient laboratory space utilization
  8. 8
    Suitable for hydrothermal synthesis, high pressure digestion, and sample pretreatment
  9. 9
    Supports rapid digestion of difficult to dissolve, insoluble, and volatile samples
  10. 10
    Suitable for trace element analysis, catalyst preparation, and material synthesis
  11. 11
    Useful for chemical, environmental, geological, biomedical, petrochemical, and food testing laboratories
  12. 12
    Recommended heating rate of ≤5°C/min helps minimize sudden pressure increases during heating
  13. 13
    Designed for controlled laboratory operation with proper filling limits and pressure precautions
Where it's used

Applications

  • Hydrothermal Synthesis: Suitable for controlled hydrothermal reactions used in material synthesis and chemical research.
  • Nanomaterial Research: Supports small scale preparation and study of nanomaterials under elevated temperature and pressure conditions.
  • Catalyst Preparation: Useful for synthesizing and evaluating catalysts and related materials in research laboratories.
  • Chemical Research: Suitable for closed vessel reactions involving elevated temperature and pressure during laboratory experiments.
  • Sample Digestion: Supports digestion and pretreatment of difficult to dissolve, insoluble, and volatile samples.
  • Trace Element Analysis: Useful for sample preparation before trace element testing and analytical procedures.
Hydrothermal Autoclave HRA-10

LET'S EQUIP
YOUR LABORATORY

View product online

+1 581 465 8405

www.labotemp.com · info@labotemp.com

144 E, Midwest Avenue, Casper WY 82601, USA

More about this product

Standard Accessories

  • PPL Liner / PTFE Liner
More about this product

Optional Accessories

  • Dual Layer Reactor Holder