ISO & CE Certified • Global Supply Chain • Comprehensive Warranty
WhatsApp Us!
Request Quote!
0
Ion Chromatograph LIO-101
Ion Chromatograph

Ion Chromatograph LIO-101

Labotemp Ion Chromatograph LIO 101 provides an integrated analytical platform for the separation and detection of inorganic ions in water, environmental, industrial, food, pharmaceutical, and research samples. The system combines a high pressure low pulse dual plunger pump, injection system, ion chromatography columns, electrolytic suppressor, column temperature oven, and conductivity detector for reliable ion analysis.

Designed as versatile Ion Chromatography Equipment, LIO 101 supports both suppressed and non suppressed conductivity detection and can be configured for different analytical requirements. Its touchscreen computer control, automatic temperature management, software based analysis, real time monitoring, and automatic flow path maintenance support convenient operation and consistent analytical workflows. The system can be used for the determination of common cations and anions including Li⁺, Na⁺, NH₄⁺, K⁺, Mg²⁺, Ca²⁺, F⁻, Cl⁻, Br⁻, NO₂⁻, NO₃⁻, PO₄³⁻, SO₃²⁻, and SO₄²⁻.  

Why Choose Labotemp Ion Chromatograph LIO 101?

✓ Integrated Ion Analysis System: Combines pumping, injection, separation, suppression, temperature control, detection, and data processing in one analytical platform.
✓ Suppressed Conductivity Detection: Electrolytic suppression supports conductivity based ion detection with reduced background interference.
✓ Touchscreen Computer Control: Provides instrument monitoring, parameter adjustment, real time data display, automated analysis, and data processing through an integrated control system.

$17400
Datasheet

Specifications Ion Chromatograph LIO-101

Pump and Flow Control

Pump Type : High pressure low pulse dual plunger series pump

Pump Type
High pressure low pulse dual plunger series pump

Pump Head Material : All PEEK

Pump Head Material
All PEEK

Pressure Range : 0 to 35 MPa

Pressure Range
0 to 35 MPa

Flow Rate Setting Range : 0.001 to 10.000 mL/min

Flow Rate Setting Range
0.001 to 10.000 mL/min

Flow Rate Setting Error : 0.1% at 1.0 mL/min

Flow Rate Setting Error
0.1% at 1.0 mL/min

Flow Rate Stability Error : 0.1% at 1.0 mL/min

Flow Rate Stability Error
0.1% at 1.0 mL/min
Suppression and Column Temperature

Suppressor Type : Electrochemical automatic regeneration solid phase suppressor

Suppressor Type
Electrochemical automatic regeneration solid phase suppressor

Dynamic Inhibition Capacity : 100 μeq/min

Dynamic Inhibition Capacity
100 μeq/min

Inhibition Background : 0.6 μS/cm

Inhibition Background
0.6 μS/cm

Inhibitor Background Noise : 6 nS/cm

Inhibitor Background Noise
6 nS/cm

Suppressor Dead Volume : 50 μL

Suppressor Dead Volume
50 μL

Current Range : 0 to 300 mA

Current Range
0 to 300 mA

Current Setting Increment : 0.1 mA

Current Setting Increment
0.1 mA

Column Oven Temperature Range : Room temperature +5°C to 85°C

Column Oven Temperature Range
Room temperature +5°C to 85°C

Temperature Setting Error : ±0.271°C

Temperature Setting Error
±0.271°C

Temperature Control Stability : ±0.029°C/h

Temperature Control Stability
±0.029°C/h
Conductivity Detection

Detector Type : Digital bipolar pulse conductivity detector

Detector Type
Digital bipolar pulse conductivity detector

Conductivity Detection Range : 0 to 15,000 μS/cm

Conductivity Detection Range
0 to 15,000 μS/cm

Detection Cell Volume : ≤0.3 μL

Detection Cell Volume
≤0.3 μL

Baseline Noise : ≤0.1%

Baseline Noise
≤0.1%

Baseline Drift : ≤0.8% FS/30 min

Baseline Drift
≤0.8% FS/30 min

Qualitative Repeatability : RSD <0.21%

Qualitative Repeatability
RSD <0.21%

Detection Limit for Chloride : ≤0.0005 μg/mL

Detection Limit for Chloride
≤0.0005 μg/mL

Compatible Column Lengths : 250 mm and 150 mm anion exchange chromatography columns

Compatible Column Lengths
250 mm and 150 mm anion exchange chromatography columns

Linear Range : ≥10²

Linear Range
≥10²

Linear Correlation Coefficient : ≥0.999

Linear Correlation Coefficient
≥0.999

Retention Time Repeatability Error : ≤1.0% for NO₃⁻, SO₄²⁻, Na⁺, and Ca²⁺

Retention Time Repeatability Error
≤1.0% for NO₃⁻, SO₄²⁻, Na⁺, and Ca²⁺
System Configuration

Power Supply : 220V, 50/60Hz or 110V, 60Hz

Power Supply
220V, 50/60Hz or 110V, 60Hz

Detection Modes : Suppressed and non suppressed conductivity detection

Detection Modes
Suppressed and non suppressed conductivity detection

Control Interface : Computer interface and touchscreen

Control Interface
Computer interface and touchscreen

Display : 7.0 inch touchscreen

Display
7.0 inch touchscreen

Data Acquisition : 24 bit A/D acquisition

Data Acquisition
24 bit A/D acquisition

Flow Path Material : All PEEK flow path

Flow Path Material
All PEEK flow path

Column Oven : Built in

Column Oven
Built in

Data Processing : PC based chromatography data software

Data Processing
PC based chromatography data software

Remote Control : Supported through PC

Remote Control
Supported through PC

Automatic Analysis : Supported

Automatic Analysis
Supported
Physical Details

Net Weight : 45 kg

Net Weight
45 kg

Gross Weight : 48 kg

Gross Weight
48 kg

Package Dimensions : 700 × 710 × 750 mm

Package Dimensions
700 × 710 × 750 mm

Features Ion Chromatograph LIO-101

  • 0 to 15,000 μS/cm Conductivity Range ➤ 0 to 15,000 μS/cm Conductivity Range
  • Integrated ion chromatography system combining pumping, injection, separation, suppression, conductivity detection, column temperature control, and data processing ➤ Integrated ion chromatography system combining pumping, injection, separation, suppression, conductivity detection, column temperature control, and data processing
  • Low pulse dual plunger pump provides stable eluent delivery for ion separation ➤ Low pulse dual plunger pump provides stable eluent delivery for ion separation
  • All PEEK flow path provides compatibility with the system's analytical flow path requirements ➤ All PEEK flow path provides compatibility with the system's analytical flow path requirements
  • Electrochemical automatic regeneration suppressor supports suppressed conductivity detection ➤ Electrochemical automatic regeneration suppressor supports suppressed conductivity detection
  • Digital bipolar pulse conductivity detector provides sensitive detection of separated ions ➤ Digital bipolar pulse conductivity detector provides sensitive detection of separated ions
  • Built in column oven maintains controlled temperature conditions during chromatographic separation ➤ Built in column oven maintains controlled temperature conditions during chromatographic separation
  • 7 inch touchscreen interface provides convenient instrument control and parameter monitoring ➤ 7 inch touchscreen interface provides convenient instrument control and parameter monitoring
  • Real time monitoring of operating parameters and analytical status ➤ Real time monitoring of operating parameters and analytical status
  • Automatic temperature control provides stable conditions for the separation column ➤ Automatic temperature control provides stable conditions for the separation column
  • Automatic flow path rinsing helps simplify routine system maintenance ➤ Automatic flow path rinsing helps simplify routine system maintenance
  • High pressure six way valve supports controlled sample injection and flow switching ➤ High pressure six way valve supports controlled sample injection and flow switching
  • Anion chromatography column and anion protection column are included in the standard configuration ➤ Anion chromatography column and anion protection column are included in the standard configuration
  • 24 bit A/D acquisition supports high precision acquisition and processing of detector signals ➤ 24 bit A/D acquisition supports high precision acquisition and processing of detector signals
  • PC based software supports instrument control, data acquisition, chromatogram processing, and analysis ➤ PC based software supports instrument control, data acquisition, chromatogram processing, and analysis
  • Remote control functionality allows instrument operation through a connected computer ➤ Remote control functionality allows instrument operation through a connected computer
  • Supports analysis of common inorganic cations and anions for environmental, water quality, food, industrial, and research applications ➤ Supports analysis of common inorganic cations and anions for environmental, water quality, food, industrial, and research applications

Applications Ion Chromatograph LIO-101

  • Environmental Water Analysis: Suitable for determination of inorganic cations and anions in drinking water, wastewater, groundwater, and other environmental water samples Environmental Water Analysis
    Suitable for determination of inorganic cations and anions in drinking water, wastewater, groundwater, and other environmental water samples
  • Water Quality Testing: Supports analysis of fluoride, chloride, bromide, nitrate, nitrite, phosphate, sulfate, lithium, sodium, ammonium, potassium, magnesium, and calcium in water samples Water Quality Testing
    Supports analysis of fluoride, chloride, bromide, nitrate, nitrite, phosphate, sulfate, lithium, sodium, ammonium, potassium, magnesium, and calcium in water samples
  • Atmospheric and Particulate Analysis: Applicable to analysis of water soluble ions associated with atmospheric particulate matter, supporting environmental monitoring applications Atmospheric and Particulate Analysis
    Applicable to analysis of water soluble ions associated with atmospheric particulate matter, supporting environmental monitoring applications
  • Pharmaceutical Analysis: Suitable for analysis of inorganic ionic components and impurities in pharmaceutical ingredients and finished products Pharmaceutical Analysis
    Suitable for analysis of inorganic ionic components and impurities in pharmaceutical ingredients and finished products
  • Food and Beverage Testing: Supports ion analysis in food and beverage samples, including inorganic ions, organic acids, and selected contaminants Food and Beverage Testing
    Supports ion analysis in food and beverage samples, including inorganic ions, organic acids, and selected contaminants
  • Hazardous Waste Analysis: Applicable to analysis of inorganic ions in hazardous waste and leachate samples Hazardous Waste Analysis
    Applicable to analysis of inorganic ions in hazardous waste and leachate samples

Standard Accessories

  • Main Instrument- 1 unit ➤ Main Instrument- 1 unit
  • Low Flow Rate Pulsed Double Plunger Pump- 1 piece ➤ Low Flow Rate Pulsed Double Plunger Pump- 1 piece
  • Conductivity Detector- 1 piece ➤ Conductivity Detector- 1 piece
  • Anion Chromatography Column- 1 piece ➤ Anion Chromatography Column- 1 piece
  • Anion Protection Column- 1 piece ➤ Anion Protection Column- 1 piece
  • Anion Suppressor- 1 piece ➤ Anion Suppressor- 1 piece
  • Built In Column Oven- 1 piece ➤ Built In Column Oven- 1 piece
  • High Pressure Six Way Valve- 1 piece ➤ High Pressure Six Way Valve- 1 piece
  • Workstation- 1 piece ➤ Workstation- 1 piece
  • Spare Parts- 1 batch ➤ Spare Parts- 1 batch

Optional Accessories

  • Liquid Autosampler YAS 180 ➤ Liquid Autosampler YAS 180
  • Computer and Printer ➤ Computer and Printer