Why choose
Biosafety Cabinet Class 2 Type B2 LBS-302?

  1. 1
    UV Sterilization & Timer
  2. 2
    100% air exhaust system provides complete external exhaust without internal air recirculation.
  3. 3
    Negative-pressure work area helps prevent contaminated air leakage and supports biosafety.
LBS-302

Biosafety Cabinet Class II

Biosafety Cabinet Class 2 Type B2 LBS-302
Biosafety Cabinet Class 2 Type B2 LBS-302
Overview

Product
Description

Product overview

Biosafety Cabinet Class 2 Type B2 LBS-302

Labotemp Biosafety Cabinet Class 2 Type B2 LBS-302 is a high-performance biological safety cabinet designed to provide protection for operators, samples, and the surrounding environment during biological laboratory procedures. Featuring a 100% air exhaust system and negative-pressure work area, this cabinet directs cabinet air through HEPA filtration for external exhaust. The biosafety cabinet with window configuration provides a side window for improved visibility while maintaining controlled working conditions. It is suitable for biological safety laboratories and applications involving appropriate volatile chemicals and radioactive materials.

The LBS-302 features a 610 × 550 × 600 mm internal workspace, dual H14 HEPA filters with ≥99.995% efficiency at 0.3 μm, and a 7-inch LCD touchscreen for real-time monitoring of airflow velocity, front-window status, temperature, filter and UV lamp life, and system working status. The motorized front window includes control and travel-limit protection, while the removable 304 stainless steel work surface facilitates cleaning and disinfection. UV sterilization with timer, air velocity sensing, audio-visual alarms, safety interlocks, power-failure memory, standard exhaust blower, and 9 m exhaust duct provide convenient operation and controlled exhaust management.

Why Choose Labotemp Biosafety Cabinet Class 2 Type B2 LBS-302?

✓ Biosafety Cabinet With Window: Side window improves visibility into the working area.
✓ Advanced Monitoring: 7-inch LCD touchscreen and air velocity sensor enable real-time system monitoring.
✓ Complete Exhaust Configuration: Includes exhaust blower and 9 m exhaust duct as standard.

Technical data · LBS-302

Complete Specifications

Biosafety Cabinet Class 2 Type B2 LBS-302
No.SpecificationValue
Cabinet Specifications
1Product TypeClass II Type B2 Biological Safety Cabinet
2Internal Size (W×D×H)610 × 550 × 600 mm
3External Size (W×D×H)710 × 760 × 2050 mm
4Maximum Opening370 mm
5Work Surface Height750 mm
6Main BodyElectro-galvanized steel with antimicrobial powder coating
7Work Surface304 stainless steel
8Front WindowMotorized, toughened glass
9Side WindowIncluded
Airflow & Filtration System
10Airflow Mode100% Air Exhaust
11Downflow Velocity0.35 ± 0.025 m/s
12Inflow Velocity0.52 ± 0.025 m/s
13Inflow Air Volume240 m³/h (141 CFM)
14Downflow Air Volume560 m³/h (330 CFM)
15Exhaust Air Volume800 m³/h (471 CFM)
16HEPA Filter2 pcs H14 HEPA filters, ≥99.995% efficiency at 0.3 μm
17Cleanliness GradeClass 100 (ISO 14644.1 Class 5)
Control & Safety System
18Display7-inch LCD Touch Screen
19AlarmAbnormal airflow velocity, HEPA filter failure, UV lamp failure, front window at unsafe height
20Air Velocity MonitoringAir velocity sensor with real-time monitoring and display
21UV Lamp15 W × 1, 253.7 nm, UV life indicator and UV timer
22LED Lamp10 W × 2
23Safety InterlockUV lamp/front window; UV lamp/blower & LED lamp; blower/front window
24Power-Failure MemoryIncluded
25Front Window OperationMotorized with control and travel-limit protection
26UV SterilizationUV sterilization and timing function
Electrical & Performance
27Maximum Consumption350 W, excluding socket consumption
28Power SupplyAC 220 V ±10%, 50/60 Hz; 110 V ±10%, 60 Hz
29Illumination≥900 Lux
30Sound Emission≤65 dB(A)
31Vibration of Work Surface≤2 μm
Weight & Shipping
32Net Weight140 kg (Main Unit); 65 kg (Exhaust Blower)
33Gross Weight175 kg (Main Unit); 80 kg (Exhaust Blower)
34Shipping Size – Main Unit (W×D×H)850 × 990 × 1640 mm
35Shipping Size – Exhaust Blower730 × 660 × 500 mm
36Shipping Volume1.62 m³
What's included

Features

  1. 1
    UV Sterilization & Timer
  2. 2
    100% air exhaust system provides complete external exhaust without internal air recirculation.
  3. 3
    Negative-pressure work area helps prevent contaminated air leakage and supports biosafety.
  4. 4
    Dual H14 HEPA filters provide ≥99.995% filtration efficiency at 0.3 μm.
  5. 5
    Side window provides improved visibility of the working area.
  6. 6
    7-inch LCD touchscreen enables real-time monitoring of front window status, airflow velocity, temperature, filter and UV lamp life, and system working status.
  7. 7
    Air velocity sensor provides real-time airflow monitoring and precise control.
  8. 8
    Motorized front window features control and travel-limit protection for convenient operation.
  9. 9
    UV sterilization and timing functions support scheduled cabinet decontamination.
  10. 10
    Audio and visual alarms indicate abnormal airflow velocity, HEPA filter failure, UV lamp failure, and unsafe front-window height.
  11. 11
    Safety interlocks coordinate the UV lamp, front window, blower, and LED lamp.
  12. 12
    Power-failure memory retains operating information after power interruption.
  13. 13
    Standard foot switch allows convenient up-and-down adjustment of the motorized front window.
  14. 14
    Removable 304 stainless steel work surface facilitates cleaning and disinfection.
  15. 15
    Standard exhaust blower and 9 m exhaust duct support the 100% external exhaust configuration.
  16. 16
    Optional upgraded LED lamp provides RG0 blue-light protection, anti-glare eye protection, and high color rendering.
  17. 17
    Optional gas tap, water tap, pressure sensor, IV bar with hooks, ULPA filter, and DC blower allow flexible configuration. 
Where it's used

Applications

Biological Safety Laboratories: Suitable for laboratory procedures requiring protection of operators, samples, and the surrounding environment from biological hazards.

Microbiology Laboratories: Used for handling and processing biological samples under controlled airflow and negative-pressure conditions.

Biotechnology & Research Laboratories: Supports biological research, sample handling, and experimental procedures involving potentially hazardous biological materials.

Pharmaceutical Laboratories: Suitable for laboratory processes involving biological materials where controlled containment and protection are required.

Clinical & Diagnostic Laboratories: Used for handling and processing biological specimens in controlled laboratory environments.

Volatile Chemical Applications: The 100% external exhaust configuration is suitable for appropriate applications involving volatile chemical hazards alongside biological work.

Radioactive Material Applications: Suitable for certain biological procedures involving radioactive nuclides where a fully exhausted cabinet configuration is required.

Quality Control Laboratories: Supports controlled sample handling and laboratory procedures where operator, product, and environmental protection are required.

Biosafety Cabinet Class 2 Type B2 LBS-302

LET'S EQUIP
YOUR LABORATORY

View product online

+1 581 465 8405

www.labotemp.com · info@labotemp.com

144 E, Midwest Avenue, Casper WY 82601, USA

More about this product

Standard Accessories

  1. 1
    Side Window
  2. 2
    Base Stand
  3. 3
    Air Velocity Sensor
  4. 4
    LCD Touch Screen
  5. 5
    LED Lamp ×2
  6. 6
    UV Lamp ×1
  7. 7
    Explosion-Proof/Waterproof Socket ×1
  8. 8
    Motorized Front Window
  9. 9
    Footmaster Caster
  10. 10
    Foot Switch
  11. 11
    Removable Shallow-Plate Stainless Steel Work Surface
  12. 12
    Exhaust Blower
  13. 13
    9 m Exhaust Duct (Φ305 mm)
  14. 14
    Magnetic File Folder
More about this product

Optional Accessories

  1. 1
    Gas Tap
  2. 2
    Water Tap
  3. 3
    Pressure Sensor
  4. 4
    IV Bar With Hooks
  5. 5
    ULPA Filter
  6. 6
    Upgraded LED Lamp
  7. 7
    DC Blower