Labotemp Biosafety Cabinet Class 2 Type B2 LBS-302 is a high-performance biological safety cabinet designed to provide protection for operators, samples, and the surrounding environment during biological laboratory procedures. Featuring a 100% air exhaust system and negative-pressure work area, this cabinet directs cabinet air through HEPA filtration for external exhaust. The biosafety cabinet with window configuration provides a side window for improved visibility while maintaining controlled working conditions. It is suitable for biological safety laboratories and applications involving appropriate volatile chemicals and radioactive materials.

The LBS-302 features a 610 × 550 × 600 mm internal workspace, dual H14 HEPA filters with ≥99.995% efficiency at 0.3 μm, and a 7-inch LCD touchscreen for real-time monitoring of airflow velocity, front-window status, temperature, filter and UV lamp life, and system working status. The motorized front window includes control and travel-limit protection, while the removable 304 stainless steel work surface facilitates cleaning and disinfection. UV sterilization with timer, air velocity sensing, audio-visual alarms, safety interlocks, power-failure memory, standard exhaust blower, and 9 m exhaust duct provide convenient operation and controlled exhaust management.

Why Choose Labotemp Biosafety Cabinet Class 2 Type B2 LBS-302?

✓ Biosafety Cabinet With Window: Side window improves visibility into the working area.
✓ Advanced Monitoring: 7-inch LCD touchscreen and air velocity sensor enable real-time system monitoring.
✓ Complete Exhaust Configuration: Includes exhaust blower and 9 m exhaust duct as standard.

$5696
Datasheet

Specifications Biosafety Cabinet Class 2 Type B2 LBS-302

Cabinet Specifications

Product Type : Class II Type B2 Biological Safety Cabinet

Product Type
Class II Type B2 Biological Safety Cabinet

Internal Size (W×D×H) : 610 × 550 × 600 mm

Internal Size (W×D×H)
610 × 550 × 600 mm

External Size (W×D×H) : 710 × 760 × 2050 mm

External Size (W×D×H)
710 × 760 × 2050 mm

Maximum Opening : 370 mm

Maximum Opening
370 mm

Work Surface Height : 750 mm

Work Surface Height
750 mm

Main Body : Electro-galvanized steel with antimicrobial powder coating

Main Body
Electro-galvanized steel with antimicrobial powder coating

Work Surface : 304 stainless steel

Work Surface
304 stainless steel

Front Window : Motorized, toughened glass

Front Window
Motorized, toughened glass

Side Window : Included

Side Window
Included
Airflow & Filtration System

Airflow Mode : 100% Air Exhaust

Airflow Mode
100% Air Exhaust

Downflow Velocity : 0.35 ± 0.025 m/s

Downflow Velocity
0.35 ± 0.025 m/s

Inflow Velocity : 0.52 ± 0.025 m/s

Inflow Velocity
0.52 ± 0.025 m/s

Inflow Air Volume : 240 m³/h (141 CFM)

Inflow Air Volume
240 m³/h (141 CFM)

Downflow Air Volume : 560 m³/h (330 CFM)

Downflow Air Volume
560 m³/h (330 CFM)

Exhaust Air Volume : 800 m³/h (471 CFM)

Exhaust Air Volume
800 m³/h (471 CFM)

HEPA Filter : 2 pcs H14 HEPA filters, ≥99.995% efficiency at 0.3 μm

HEPA Filter
2 pcs H14 HEPA filters, ≥99.995% efficiency at 0.3 μm

Cleanliness Grade : Class 100 (ISO 14644.1 Class 5)

Cleanliness Grade
Class 100 (ISO 14644.1 Class 5)
Control & Safety System

Display : 7-inch LCD Touch Screen

Display
7-inch LCD Touch Screen

Alarm : Abnormal airflow velocity, HEPA filter failure, UV lamp failure, front window at unsafe height

Alarm
Abnormal airflow velocity, HEPA filter failure, UV lamp failure, front window at unsafe height

Air Velocity Monitoring : Air velocity sensor with real-time monitoring and display

Air Velocity Monitoring
Air velocity sensor with real-time monitoring and display

UV Lamp : 15 W × 1, 253.7 nm, UV life indicator and UV timer

UV Lamp
15 W × 1, 253.7 nm, UV life indicator and UV timer

LED Lamp : 10 W × 2

LED Lamp
10 W × 2

Safety Interlock : UV lamp/front window; UV lamp/blower & LED lamp; blower/front window

Safety Interlock
UV lamp/front window; UV lamp/blower & LED lamp; blower/front window

Power-Failure Memory : Included

Power-Failure Memory
Included

Front Window Operation : Motorized with control and travel-limit protection

Front Window Operation
Motorized with control and travel-limit protection

UV Sterilization : UV sterilization and timing function

UV Sterilization
UV sterilization and timing function
Electrical & Performance

Maximum Consumption : 350 W, excluding socket consumption

Maximum Consumption
350 W, excluding socket consumption

Power Supply : AC 220 V ±10%, 50/60 Hz; 110 V ±10%, 60 Hz

Power Supply
AC 220 V ±10%, 50/60 Hz; 110 V ±10%, 60 Hz

Illumination : ≥900 Lux

Illumination
≥900 Lux

Sound Emission : ≤65 dB(A)

Sound Emission
≤65 dB(A)

Vibration of Work Surface : ≤2 μm

Vibration of Work Surface
≤2 μm
Weight & Shipping

Net Weight : 140 kg (Main Unit); 65 kg (Exhaust Blower)

Net Weight
140 kg (Main Unit); 65 kg (Exhaust Blower)

Gross Weight : 175 kg (Main Unit); 80 kg (Exhaust Blower)

Gross Weight
175 kg (Main Unit); 80 kg (Exhaust Blower)

Shipping Size – Main Unit (W×D×H) : 850 × 990 × 1640 mm

Shipping Size – Main Unit (W×D×H)
850 × 990 × 1640 mm

Shipping Size – Exhaust Blower : 730 × 660 × 500 mm

Shipping Size – Exhaust Blower
730 × 660 × 500 mm

Shipping Volume : 1.62 m³

Shipping Volume
1.62 m³

Features Biosafety Cabinet Class 2 Type B2 LBS-302

  • UV Sterilization & Timer ➤ UV Sterilization & Timer
  • 100% air exhaust system provides complete external exhaust without internal air recirculation. ➤ 100% air exhaust system provides complete external exhaust without internal air recirculation.
  • Negative-pressure work area helps prevent contaminated air leakage and supports biosafety. ➤ Negative-pressure work area helps prevent contaminated air leakage and supports biosafety.
  • Dual H14 HEPA filters provide ≥99.995% filtration efficiency at 0.3 μm. ➤ Dual H14 HEPA filters provide ≥99.995% filtration efficiency at 0.3 μm.
  • Side window provides improved visibility of the working area. ➤ Side window provides improved visibility of the working area.
  • 7-inch LCD touchscreen enables real-time monitoring of front window status, airflow velocity, temperature, filter and UV lamp life, and system working status. ➤ 7-inch LCD touchscreen enables real-time monitoring of front window status, airflow velocity, temperature, filter and UV lamp life, and system working status.
  • Air velocity sensor provides real-time airflow monitoring and precise control. ➤ Air velocity sensor provides real-time airflow monitoring and precise control.
  • Motorized front window features control and travel-limit protection for convenient operation. ➤ Motorized front window features control and travel-limit protection for convenient operation.
  • UV sterilization and timing functions support scheduled cabinet decontamination. ➤ UV sterilization and timing functions support scheduled cabinet decontamination.
  • Audio and visual alarms indicate abnormal airflow velocity, HEPA filter failure, UV lamp failure, and unsafe front-window height. ➤ Audio and visual alarms indicate abnormal airflow velocity, HEPA filter failure, UV lamp failure, and unsafe front-window height.
  • Safety interlocks coordinate the UV lamp, front window, blower, and LED lamp. ➤ Safety interlocks coordinate the UV lamp, front window, blower, and LED lamp.
  • Power-failure memory retains operating information after power interruption. ➤ Power-failure memory retains operating information after power interruption.
  • Standard foot switch allows convenient up-and-down adjustment of the motorized front window. ➤ Standard foot switch allows convenient up-and-down adjustment of the motorized front window.
  • Removable 304 stainless steel work surface facilitates cleaning and disinfection. ➤ Removable 304 stainless steel work surface facilitates cleaning and disinfection.
  • Standard exhaust blower and 9 m exhaust duct support the 100% external exhaust configuration. ➤ Standard exhaust blower and 9 m exhaust duct support the 100% external exhaust configuration.
  • Optional upgraded LED lamp provides RG0 blue-light protection, anti-glare eye protection, and high color rendering. ➤ Optional upgraded LED lamp provides RG0 blue-light protection, anti-glare eye protection, and high color rendering.
  • Optional gas tap, water tap, pressure sensor, IV bar with hooks, ULPA filter, and DC blower allow flexible configuration.  ➤ Optional gas tap, water tap, pressure sensor, IV bar with hooks, ULPA filter, and DC blower allow flexible configuration. 

Applications Biosafety Cabinet Class 2 Type B2 LBS-302

  • Biological Safety Laboratories: Suitable for laboratory procedures requiring protection of operators, samples, and the surrounding environment from biological hazards Biological Safety Laboratories
    Suitable for laboratory procedures requiring protection of operators, samples, and the surrounding environment from biological hazards
  • Microbiology Laboratories: Used for handling and processing biological samples under controlled airflow and negative-pressure conditions Microbiology Laboratories
    Used for handling and processing biological samples under controlled airflow and negative-pressure conditions
  • Biotechnology & Research Laboratories: Supports biological research, sample handling, and experimental procedures involving potentially hazardous biological materials Biotechnology & Research Laboratories
    Supports biological research, sample handling, and experimental procedures involving potentially hazardous biological materials
  • Pharmaceutical Laboratories: Suitable for laboratory processes involving biological materials where controlled containment and protection are required Pharmaceutical Laboratories
    Suitable for laboratory processes involving biological materials where controlled containment and protection are required
  • Clinical & Diagnostic Laboratories: Used for handling and processing biological specimens in controlled laboratory environments Clinical & Diagnostic Laboratories
    Used for handling and processing biological specimens in controlled laboratory environments
  • Volatile Chemical Applications: The 100% external exhaust configuration is suitable for appropriate applications involving volatile chemical hazards alongside biological work Volatile Chemical Applications
    The 100% external exhaust configuration is suitable for appropriate applications involving volatile chemical hazards alongside biological work
  • Radioactive Material Applications: Suitable for certain biological procedures involving radioactive nuclides where a fully exhausted cabinet configuration is required Radioactive Material Applications
    Suitable for certain biological procedures involving radioactive nuclides where a fully exhausted cabinet configuration is required
  • Quality Control Laboratories: Supports controlled sample handling and laboratory procedures where operator, product, and environmental protection are required Quality Control Laboratories
    Supports controlled sample handling and laboratory procedures where operator, product, and environmental protection are required

Standard Accessories

  • Side Window ➤ Side Window
  • Base Stand ➤ Base Stand
  • Air Velocity Sensor ➤ Air Velocity Sensor
  • LCD Touch Screen ➤ LCD Touch Screen
  • LED Lamp ×2 ➤ LED Lamp ×2
  • UV Lamp ×1 ➤ UV Lamp ×1
  • Explosion-Proof/Waterproof Socket ×1 ➤ Explosion-Proof/Waterproof Socket ×1
  • Motorized Front Window ➤ Motorized Front Window
  • Footmaster Caster ➤ Footmaster Caster
  • Foot Switch ➤ Foot Switch
  • Removable Shallow-Plate Stainless Steel Work Surface ➤ Removable Shallow-Plate Stainless Steel Work Surface
  • Exhaust Blower ➤ Exhaust Blower
  • 9 m Exhaust Duct (Φ305 mm) ➤ 9 m Exhaust Duct (Φ305 mm)
  • Magnetic File Folder ➤ Magnetic File Folder

Optional Accessories

  • Gas Tap ➤ Gas Tap
  • Water Tap ➤ Water Tap
  • Pressure Sensor ➤ Pressure Sensor
  • IV Bar With Hooks ➤ IV Bar With Hooks
  • ULPA Filter ➤ ULPA Filter
  • Upgraded LED Lamp ➤ Upgraded LED Lamp
  • DC Blower ➤ DC Blower