Labotemp CO2 Incubator for Cell Culture LCI-102 provides a controlled environment for cell cultivation, supporting stable temperature and carbon dioxide regulation for laboratory research. With an 80 L chamber capacity, a temperature control range of ambient temperature +3°C to 60°C, and adjustable CO2 concentration from 0% to 20%, this incubator supports cell culture workflows requiring controlled incubation conditions. Temperature fluctuation is ±0.1°C and temperature uniformity is ±0.3°C at 37°C, helping maintain consistent conditions throughout the chamber.
The LCI-102 features a 4.3-inch touchscreen, an infrared CO2 sensor, and a PT100 temperature sensor for monitoring and controlling key parameters. Its ultraviolet sterilization function and CO2 inlet microbial filter, with filtration efficiency up to 99.99% for particles larger than 0.3 µm, help reduce contamination risks during routine operation. Six-sided heating, including the outer door, helps prevent condensation and improves chamber visibility. Real-time and historical data curves, USB data export in CSV and PDF formats, fault alarms, and three-level access management support monitoring, recordkeeping, and controlled operation in cell culture laboratories.
Why Choose Labotemp CO2 Incubator for Cell Culture LCI-102?
✓ Precise Temperature Control: Maintains temperature fluctuation of ±0.1°C at 37°C for controlled incubation.
✓ Adjustable CO2 Regulation: Offers a 0%–20% CO2 control range with 0.1% control accuracy.
✓ Contamination Control Features: Combines UV sterilization with a CO2 inlet microbial filter for additional contamination control.
| No. | Specification | Value |
|---|---|---|
| General Specifications | ||
| 1 | Product Name | CO2 Incubator for Cell Culture |
| 2 | Chamber Volume | 85 L |
| 3 | Power Supply | 220 V / 50 Hz |
| 4 | Working Environment Temperature | 5°C to 30°C |
| 5 | Inner Chamber Dimensions (W × D × H) | 400 × 415 × 515 mm |
| 6 | External Dimensions (W × D × H) | 590 × 600 × 920 mm |
| Temperature Control | ||
| 7 | Heating Method | Air Sleeve Heating with Microcomputer PID Control |
| 8 | Temperature Control Range | Ambient Temperature +3°C to 60°C |
| 9 | Temperature Fluctuation | ±0.1°C at 37°C |
| 10 | Temperature Uniformity | ±0.3°C at 37°C |
| 11 | Temperature Sensor | PT100 |
| 12 | Temperature Recovery Time | Returns to 37°C within 30 seconds after door opening |
| CO2 Control | ||
| 13 | CO2 Control Range | 0% to 20% |
| 14 | CO2 Control Accuracy | 0.1% |
| 15 | CO2 Sensor | Infrared (IR) CO2 Sensor |
| 16 | CO2 Recovery Time | Returns to 5% within 30 seconds after door opening |
| 17 | CO2 Inlet Filter | Microbial Filter with 99.99% Filtration Efficiency for Particles Larger Than 0.3 µm |
| Humidity | ||
| 18 | Relative Humidity | ≥90% by Natural Evaporation |
| Sterilization and Contamination Control | ||
| 19 | Sterilization Method | Ultraviolet (UV) Sterilization |
| 20 | UV Sterilization Function | Periodic Internal Chamber Sterilization |
| Monitoring and Control | ||
| 21 | Display | 4.3-Inch Touchscreen |
| 22 | Temperature and CO2 Monitoring | Real-Time Monitoring |
| 23 | Data Display | Real-Time and Historical Curves |
| 24 | Data Recording | Available |
| 25 | Data Export | USB Flash Drive, CSV and PDF Formats |
| 26 | Alarm System | Set Temperature Alarm, Over-Temperature Alarm, CO2 Concentration Alarm, Fault Alarm |
| 27 | Alarm Type | Text and Sound Alerts |
| 28 | Controller Lock | Yes |
| 29 | Permission Management | Three-Level Access Management |
| Chamber Construction | ||
| 30 | Heating System | Six-Sided Heating, Including Heated Outer Door |
| 31 | Loading Compartment | 3 Standard / 7 Maximum |
Cell Culture Laboratories: Provides controlled temperature and CO2 conditions for routine cell cultivation.
Biomedical Research: Supports cell-based experiments requiring regulated incubation conditions.
Pharmaceutical Research: Suitable for cell culture workflows used in pharmaceutical research and laboratory studies.
Biotechnology Laboratories: Supports research involving cultured cells and biological materials.
Clinical and Medical Research: Provides controlled incubation conditions for cell-based laboratory investigations.
Tissue Engineering Research: Can support cell culture stages in tissue engineering studies, subject to the specific experimental requirements.
University and Academic Laboratories: Suitable for cell culture experiments and biological research requiring temperature and CO2 control.
Cell Biology Research: Supports studies investigating cell growth, behavior, and responses under controlled incubation conditions.