Labotemp Pilot Freeze Dryer LFD-401 supports pilot-scale lyophilization for laboratory research and process development involving temperature-sensitive materials. Featuring a 0.2 m² freeze-drying area, this configuration provides a solution capacity of 3 L and water capture capacity of 4 kg per batch. Its tray system accommodates 2+1 layers, with tray dimensions of 300 × 345 mm and 70 mm spacing. Tray temperature operates from -50°C to +60°C, while its cold trap reaches a minimum temperature of -70°C. Gland-type silicone oil heating supports controlled tray heating during freeze-drying operations. Vial capacity varies according to vial diameter, accommodating up to 1,300 vials at Ø12 mm, 810 at Ø16 mm, or 430 at Ø22 mm.
Vacuum system reaches an ultimate vacuum degree of 1 Pa and includes a vacuum pump rated at 4 L/s. Process functions include low-temperature chamber pre-cooling, secondary refreezing, pressure-rise testing, adjustable vacuum control, and real-time monitoring of sample temperatures and vacuum levels. Closed-loop PID control supports thermal regulation, while freeze-drying curve management allows multi-profile storage and manual curve intervention during cycles. Additional functions include stage-specific process navigation, in-process formula adjustments, timestamped data logging, report generation, interlock safeguards, emergency protocols, and power-loss recovery. Available electrical configurations include 220 V and 110 V, both operating at 50/60 Hz, allowing selection according to site power requirements.
Why Choose Labotemp Pilot Freeze Dryer LFD-401?
✓ Pilot-Scale Processing: 0.2 m² freeze-drying area with 3 L solution capacity.
✓ Low-Temperature Cold Trap: Reaches a minimum temperature of -70°C.
✓ Controlled Freeze-Drying: Features closed-loop PID control and adjustable vacuum operation.
| No. | Specification | Value |
|---|---|---|
| General Information | ||
| 1 | Product Type | Pilot Freeze Dryer |
| 2 | Model | LFD-401 |
| 3 | Heating Type | Gland-Type Silicone Oil Heating |
| 4 | Freeze-Drying Area | 0.2 m² |
| 5 | Solution Capacity | 3 L |
| 6 | Water Capture Capacity | 4 kg/batch |
| Freeze-Drying Capacity | ||
| 7 | Vial Capacity (Ø12 mm) | 1,300 |
| 8 | Vial Capacity (Ø16 mm) | 810 |
| 9 | Vial Capacity (Ø22 mm) | 430 |
| 10 | Number of Tray Layers | 2+1 |
| 11 | Tray Dimensions (Long × Width) | 300 × 345 mm |
| 12 | Tray Spacing | 70 mm |
| 13 | Tray Temperature Range | -50°C to +60°C |
| Temperature and Vacuum Parameters | ||
| 14 | Cold Trap Minimum Temperature | -70°C |
| 15 | Ultimate Vacuum Degree | 1 Pa |
| 16 | Vacuum Pump Capacity | 4 L/s |
| 17 | Temperature Control | Closed-Loop PID Control |
| 18 | Vacuum Control | Adjustable Vacuum Control |
| Control System and Functions | ||
| 19 | Process Monitoring | Sample Temperatures and Vacuum Levels |
| 20 | Curve Management | Multi-Profile Storage and Manual Curve Intervention |
| 21 | Process Navigation | Stage-Specific Navigation |
| 22 | Formula Adjustment | In-Process Formula Adjustments |
| 23 | Pressure Testing | Pressure-Rise Test |
| 24 | Additional Functions | Low-Temperature Chamber Pre-Cooling, Secondary Refreezing |
| 25 | Data Management | Timestamped Data Logging and Report Generation |
| 26 | Safety Functions | Interlock Safeguards, Emergency Protocols and Power-Loss Recovery |
| Electrical Requirements | ||
| 27 | Power Supply Option 1 | 220 V, 50/60 Hz |
| 28 | Power Supply Option 2 | 110 V, 50/60 Hz |
| 29 | Power Consumption | 3 kW (catalogue configuration) |
| Dimensions and Weight | ||
| 30 | External Dimensions (W × D × H) | 800 × 800 × 1480 mm |
| 31 | Gross Weight | 260 kg |
| 32 | Packaging Dimensions (W × D × H) | 950 × 950 × 1700 mm |
| 33 | Permissible Ambient Temperature | ≤25°C |
Pharmaceutical Research: Supports freeze-drying development and evaluation of pharmaceutical formulations.
Biotechnology Laboratories: Supports lyophilization research involving temperature-sensitive biological materials.
Food Research and Development: Supports freeze-drying trials for food materials and product development.
Chemical Research: Supports laboratory freeze-drying processes involving suitable chemical samples.
Pilot Process Development: Supports evaluation and development of freeze-drying processes at pilot scale.