Labotemp Vacuum Freeze Drying Machine LFD-203 delivers dependable lyophilization for pharmaceutical, biotechnology, food, environmental, and research laboratories requiring larger sample capacity and consistent drying performance. This floor-standing system features a 0.12 m² freeze-drying area, four stainless steel shelves, -60°C cold trap (optional -80°C), and 2 Pa ultimate vacuum to efficiently remove moisture while preserving the structure and activity of heat-sensitive materials. Its transparent corrosion-resistant drying chamber provides clear sample visibility, making it ideal for biological specimens, vaccines, plant extracts, microorganisms, laboratory chemicals, and other valuable research samples.
Built for reliable laboratory operation, the LFD-203 integrates a 7-inch touchscreen HMI with real-time monitoring of vacuum, temperature, and freeze-drying curves, alongside USB data export for complete process documentation. The energy-efficient Secop refrigeration system ensures stable low-temperature performance, while delayed vacuum pump start, automatic parameter storage, vacuum alarms, inert gas filling port, and one-touch defrost enhance operational safety and convenience. Designed with corrosion-resistant components and an industrial-grade control system, the LFD-203 provides long-term durability and consistent freeze-drying performance for routine laboratory and pilot-scale applications.
Why Choose Labotemp Vacuum Freeze Drying Machine LFD-203?
✓ Intelligent Control: 7-inch touchscreen, real-time monitoring, freeze-drying curve display, USB data export, and automatic parameter storage.
✓ Reliable Sample Protection: Vacuum alarms, delayed pump start, inert gas filling port, and one-touch defrost support safe and stable operation.
✓ Built for Long-Term Use: Energy-efficient Secop refrigeration, corrosion-resistant construction, industrial-grade controls, and low-maintenance design ensure dependable laboratory performance.
| No. | Specification | Value |
|---|---|---|
| General Specifications | ||
| 1 | Type | Standard |
| 2 | Freeze-Drying Area | 0.12 m² |
| 3 | Cold Trap Temperature | -60°C |
| 4 | Optional Cold Trap Temperature | -80°C |
| 5 | Water Capture Capacity | 4 kg/batch |
| 6 | Standard Vacuum Degree | ≤5 Pa |
| 7 | Ultimate Vacuum Degree | 2 Pa |
| 8 | Power Consumption | 680 W |
| 9 | Optional -80°C Power Consumption | 1300 W |
| 10 | Power Supply | AC 220 V, 25 A, 50 Hz |
| 11 | Applicable Environment | Ambient temperature ≤30°C |
| 12 | Noise Level | ≤55 dB |
| Sterilization Parameters | ||
| 13 | Vial Capacity Ø12 mm | 920 vials |
| 14 | Vial Capacity Ø16 mm | 480 vials |
| 15 | Vial Capacity Ø22 mm | 260 vials |
| 16 | Freeze-Drying Process | Standard freeze drying |
| 17 | Moisture Capture | 4 kg/batch |
| 18 | Vacuum Performance | Standard vacuum ≤5 Pa; ultimate vacuum 2 Pa |
| Operation | ||
| 19 | Control Interface | 7-inch color LCD touchscreen with user-friendly HMI |
| 20 | Lock Screen Function | Yes |
| 21 | Remote Control | Optional PC/mobile remote control |
| 22 | Operating System | Industrial-grade embedded operating system |
| 23 | Data Management | Automatic storage of freeze-drying parameters, data review, USB export, deletion, and anti-loss protection |
| 24 | Process Monitoring | Real-time vacuum level, cold trap/material temperature, and freeze-drying curves |
| 25 | Data Storage | Multi-curve storage with USB data extraction |
| 26 | Refrigeration System | Secop compressor with hybrid refrigeration technology |
| 27 | Vacuum System | Stainless steel vacuum line with KF25 quick-connect clamp |
| 28 | Vacuum Pump Protection | Delayed vacuum pump start |
| 29 | Safety Protection | Vacuum alarm, power-off auto-inflation, and inert gas filling port |
| 30 | Defrost Function | One-click auxiliary heating/defrost |
| 31 | Cooling System | Axial cooling fan with dual-ball imported bearings |
| 32 | Maintenance | Magnetic maintenance panel and automated maintenance reminders |
| Physical Dimensions | ||
| 33 | Material Tray | Ø200 mm × 4 layers |
| 34 | Drying Chamber Height | 460 mm |
| 35 | External Dimensions (W × D × H) | 600 × 510 × 760 mm |
| 36 | Shipping Size – Main Machine | 680 × 640 × 930 mm |
| 37 | Shipping Size – Accessory | 300 × 300 × 500 mm |
| 38 | Main Unit Weight | 70 kg |
| 39 | Main Unit Weight with Optional -80°C Configuration | 80 kg |
| 40 | Gross Weight | 87 kg / 15 kg / 21 kg |
Pharmaceutical Research
Freeze drying of vaccines, pharmaceutical formulations, APIs, and other heat-sensitive materials requiring controlled moisture removal.
Biotechnology
Preservation of proteins, enzymes, biological samples, cultures, and other sensitive biomaterials for research and storage.
Food & Nutraceutical Research
Lyophilization of food extracts, probiotics, plant-based materials, and nutritional products while helping preserve their properties.
Clinical Laboratories
Processing and preservation of diagnostic reagents, biological specimens, and temperature-sensitive laboratory materials.
Microbiology
Drying and preservation of microbial cultures, biological preparations, and research samples under controlled vacuum conditions.
Environmental Research
Freeze drying of environmental samples, extracts, and moisture-sensitive materials for laboratory analysis and long-term preservation.
Plant & Natural Product Research
Preservation of plant extracts, botanical samples, and natural compounds while minimizing thermal degradation.
Laboratory R&D
Suitable for formulation development, process optimization, sample preparation, and pilot-scale lyophilization studies.