ISO & CE Certified • Global Supply Chain • Comprehensive Warranty
WhatsApp Us!
Request Quote!
0
Hot Air Sterilizer LHS-104
LHS-104

Hot Air Sterilizer LHS-104

Labotemp Hot Air Sterilizer LHS-104 provides controlled hot-air treatment for laboratory materials and components, supporting moisture removal, solvent removal and heat treatment of suitable metal, plastic, ceramic and other heat-resistant surfaces. A 452 L chamber and operating range from ambient temperature +5°C to 300°C accommodate varied laboratory loading requirements. Temperature resolution reaches 0.1°C, while documented fluctuation at 150°C ranges from ±0.3°C to ±0.5°C. Temperature uniformity ranges from ±1% between ambient +5°C and 105°C, and ±2% between 105°C and 300°C.

A preheating chamber warms and mixes incoming air before entry into working chamber, supporting rapid temperature rise and thermal distribution. Six adjustable fan speeds help match airflow to different loads, while drawer-style removable shelves simplify loading, unloading and cleaning. An LCD control system with backlit touch buttons supports 10-segment, 100-cycle program settings and countdown scheduling from 0–9999 minutes. Displayed information includes set temperature, actual temperature, operating status and fan speed. Dual over-temperature protection combines an integrated temperature sensor with an independent thermal cutoff switch. Standard equipment includes an RS-485 interface and air intake and exhaust filters. Chamber construction features rounded corners, a 304 stainless steel interior and an enamel-coated steel exterior.

Why Choose Labotemp Hot Air Sterilizer LHS-104?

✓ 452 L Chamber Capacity: Accommodates larger laboratory loads.
✓ Controlled Temperature Range: Operates from ambient +5°C to 300°C.
✓ Adjustable Airflow: Six fan-speed settings support varied loading needs.

$6312
Datasheet

Specifications Hot Air Sterilizer LHS-104

General Information

Product Type : Hot Air Sterilizer

Product Type
Hot Air Sterilizer

Model : LHS-104

Model
LHS-104

Chamber Capacity : 452 L

Chamber Capacity
452 L

Air Circulation : Forced Air Circulation

Air Circulation
Forced Air Circulation

Heating Design : Preheating Chamber

Heating Design
Preheating Chamber
Temperature Specifications

Temperature Range : Ambient +5°C to 300°C

Temperature Range
Ambient +5°C to 300°C

Temperature Resolution : 0.1°C

Temperature Resolution
0.1°C

Temperature Fluctuation at 150°C : ±0.3°C to ±0.5°C

Temperature Fluctuation at 150°C
±0.3°C to ±0.5°C

Temperature Uniformity : ±1% (ambient +5°C to 105°C); ±2% (105°C to 300°C)

Temperature Uniformity
±1% (ambient +5°C to 105°C); ±2% (105°C to 300°C)

Heating-Up Time to 150°C : 17–22 minutes

Heating-Up Time to 150°C
17–22 minutes
Control System and Display

Control System : Digital LCD Control System

Control System
Digital LCD Control System

Display Type : LCD

Display Type
LCD

Operating Interface : Backlit Touch Buttons

Operating Interface
Backlit Touch Buttons

Program Segments : 10

Program Segments
10

Program Cycle Capacity : 100 cycles

Program Cycle Capacity
100 cycles

Timer Range : 0–9999 min/h

Timer Range
0–9999 min/h

Displayed Parameters : Set Temperature, Actual Temperature, Operating Status and Fan Speed

Displayed Parameters
Set Temperature, Actual Temperature, Operating Status and Fan Speed
Air Circulation and Chamber Construction

Fan Speed Settings : 6 adjustable speeds

Fan Speed Settings
6 adjustable speeds

Air Distribution : Preheated and Mixed Air

Air Distribution
Preheated and Mixed Air

Shelf Design : Drawer-Style Removable Shelves

Shelf Design
Drawer-Style Removable Shelves

Chamber Corners : Rounded

Chamber Corners
Rounded

Interior Material : 304 Stainless Steel

Interior Material
304 Stainless Steel

Exterior Material : Enamel-Coated Steel Plate

Exterior Material
Enamel-Coated Steel Plate

Insulation : High-Quality Thermal Insulation Material

Insulation
High-Quality Thermal Insulation Material

Air Intake : Filter Included

Air Intake
Filter Included

Air Exhaust : Filter Included

Air Exhaust
Filter Included
Safety Features

Over-Temperature Protection : Dual Protection

Over-Temperature Protection
Dual Protection

Primary Protection : Integrated Temperature Sensor

Primary Protection
Integrated Temperature Sensor

Secondary Protection : Independent Thermal Cutoff Switch

Secondary Protection
Independent Thermal Cutoff Switch
Data Communication

Communication Interface : RS-485

Communication Interface
RS-485

Standard Interface Quantity : 1

Standard Interface Quantity
1
Electrical Requirements

Input Power : 1550–3500 W

Input Power
1550–3500 W

Voltage Configuration : 110–220 V stated in product comparison document

Voltage Configuration
110–220 V stated in product comparison document

Frequency : Not specified in supplied product brochure

Frequency
Not specified in supplied product brochure

Exact Voltage Configuration : Confirmation required

Exact Voltage Configuration
Confirmation required
Dimensions and Weight

External Dimensions : 774 × 845 × 1704 mm

External Dimensions
774 × 845 × 1704 mm

Net Weight : 145 kg

Net Weight
145 kg

Gross Weight : 174 kg

Gross Weight
174 kg

Packaging Dimensions : 854 × 965 × 1744 mm

Packaging Dimensions
854 × 965 × 1744 mm

Features Hot Air Sterilizer LHS-104

  • 452 L Chamber Capacity ➤ 452 L Chamber Capacity
  • Preheating Chamber Design ➤ Preheating Chamber Design
  • Forced Air Circulation ➤ Forced Air Circulation
  • Six-Speed Adjustable Fan ➤ Six-Speed Adjustable Fan
  • LCD Display ➤ LCD Display
  • Backlit Touch Buttons ➤ Backlit Touch Buttons
  • 10-Segment Program Settings ➤ 10-Segment Program Settings
  • 100-Cycle Program Capacity ➤ 100-Cycle Program Capacity
  • Countdown Scheduling ➤ Countdown Scheduling
  • Set and Actual Temperature Display ➤ Set and Actual Temperature Display
  • Operating Status Display ➤ Operating Status Display
  • Fan Speed Display ➤ Fan Speed Display
  • Dual Over-Temperature Protection ➤ Dual Over-Temperature Protection
  • Independent Thermal Cutoff Switch ➤ Independent Thermal Cutoff Switch
  • Removable Drawer-Style Shelves ➤ Removable Drawer-Style Shelves
  • Rounded Chamber Corners ➤ Rounded Chamber Corners
  • 304 Stainless Steel Interior ➤ 304 Stainless Steel Interior
  • Enamel-Coated Steel Exterior ➤ Enamel-Coated Steel Exterior
  • Air Intake and Exhaust Filters ➤ Air Intake and Exhaust Filters
  • RS-485 Communication Interface ➤ RS-485 Communication Interface

Applications Hot Air Sterilizer LHS-104

  • Laboratory Material Drying: Supports drying of suitable heat-resistant laboratory materials and components Laboratory Material Drying
    Supports drying of suitable heat-resistant laboratory materials and components
  • Moisture Removal: Supports removal of moisture from compatible metal, plastic, ceramic and other material surfaces Moisture Removal
    Supports removal of moisture from compatible metal, plastic, ceramic and other material surfaces
  • Solvent Removal: Supports removal of suitable solvents from material surfaces through controlled hot-air treatment Solvent Removal
    Supports removal of suitable solvents from material surfaces through controlled hot-air treatment
  • Hot-Air Treatment: Provides controlled temperature conditions for heat treatment of compatible laboratory materials Hot-Air Treatment
    Provides controlled temperature conditions for heat treatment of compatible laboratory materials
  • Laboratory Sample Preparation: Supports preparation workflows requiring controlled heating and drying of suitable materials Laboratory Sample Preparation
    Supports preparation workflows requiring controlled heating and drying of suitable materials

Standard Accessories

  • Drawer-Style Removable Shelves ➤ Drawer-Style Removable Shelves
  • RS-485 Communication Interface ➤ RS-485 Communication Interface
  • Air Intake Filter ➤ Air Intake Filter
  • Air Exhaust Filter ➤ Air Exhaust Filter

Optional Accessories

  • External Printer ➤ External Printer
  • Online Monitoring Platform ➤ Online Monitoring Platform
  • Mobile Application Monitoring ➤ Mobile Application Monitoring
  • Door Gasket ➤ Door Gasket
  • Electric heating tube ➤ Electric heating tube
  • Voltage regulator ➤ Voltage regulator