ISO & CE Certified • Global Supply Chain • Comprehensive Warranty
WhatsApp Us!
Request Quote!
0
Hydrogen Peroxide Plasma Sterilizer LPP-101
Hydrogen Peroxide Plasma Sterilizer
Hydrogen Peroxide Plasma Sterilizer
Sterilant Cartridge

Hydrogen Peroxide Plasma Sterilizer LPP-101

Labotemp Hydrogen Peroxide Plasma Sterilizer LPP-101 features a 60L chamber capacity, 50±5°C low-temperature sterilization, advanced hydrogen peroxide vapor technology, and intelligent plasma generation for safe sterilization of heat- and moisture-sensitive medical devices. Designed for hospitals, clinics, endoscopy units, dental facilities, and research laboratories, this plasma sterilizer provides effective sterilization of endoscopes, ophthalmic instruments, laparoscopic tools, electrosurgical devices, and other delicate equipment that cannot withstand conventional steam sterilization. The combination of vacuum technology and H₂O₂ sterilization ensures deep penetration into complex instruments while maintaining material compatibility and instrument integrity.

Engineered for reliable daily operation, the LPP-101 utilizes an advanced PLC control system with a touch-screen interface, automated cycle management, and real-time process monitoring for consistent sterilization performance. The corrosion-resistant aluminum alloy chamber promotes uniform temperature distribution, while precise sterilant dosing and hydrogen peroxide purification technology help maximize efficiency and safety. This low temperature plasma sterilizer leaves no toxic residues, as hydrogen peroxide decomposes into water and oxygen after sterilization. With automatic fault diagnostics, lift-door safety protection, energy-efficient operation, and fast cycle performance, the system provides dependable gas plasma sterilization for modern healthcare and laboratory environments.

Why Choose Labotemp Hydrogen Peroxide Plasma Sterilizer LPP-101?
✓ 60L Chamber Capacity: Ideal for routine instrument sterilization workloads
✓ 50±5°C Low-Temperature Operation: Protects delicate and heat-sensitive devices
✓ Intelligent PLC Control: Automated monitoring, diagnostics, and cycle management

$17802
Datasheet

Specifications Hydrogen Peroxide Plasma Sterilizer LPP-101

General Specifications

Capacity : 60 L

Capacity
60 L

Inner Chamber Material : Aluminum Alloy

Inner Chamber Material
Aluminum Alloy

Control System : PLC Control with Touch Screen Interface

Control System
PLC Control with Touch Screen Interface

Data Storage : USB (U Disk) Storage Function

Data Storage
USB (U Disk) Storage Function

Monitoring System : Real-time Process Monitoring with Automatic Fault Detection

Monitoring System
Real-time Process Monitoring with Automatic Fault Detection

Power Supply : AC 380 V, 220 V / 50 Hz

Power Supply
AC 380 V, 220 V / 50 Hz

Power Consumption : 3 kW

Power Consumption
3 kW
Sterilization Parameters

Sterilization Temperature : 50 ± 5°C

Sterilization Temperature
50 ± 5°C

Sterilization Agent : Hydrogen Peroxide + Plasma

Sterilization Agent
Hydrogen Peroxide + Plasma
Package Dimensions

Inner Chamber Size (W × H × D) : 260 × 300 × 750 mm

Inner Chamber Size (W × H × D)
260 × 300 × 750 mm

External Dimensions (L × W × H) : 700 × 730 × 1060 mm

External Dimensions (L × W × H)
700 × 730 × 1060 mm

Net Weight : 115 kg

Net Weight
115 kg

Gross Weight : 220 kg

Gross Weight
220 kg

Package Size : 1220 × 890 × 900 mm

Package Size
1220 × 890 × 900 mm

Features Hydrogen Peroxide Plasma Sterilizer LPP-101

  • 50±5°C Low-Temp Cycle ➤ 50±5°C Low-Temp Cycle
  • Lift-Door Safety Structure with obstacle detection and alarm function to enhance operator protection. ➤ Lift-Door Safety Structure with obstacle detection and alarm function to enhance operator protection.
  • PLC-Based Intelligent Control System for precise cycle control and reliable operation. ➤ PLC-Based Intelligent Control System for precise cycle control and reliable operation.
  • Touchscreen Human-Machine Interface (HMI) provides user-friendly parameter setting and monitoring. ➤ Touchscreen Human-Machine Interface (HMI) provides user-friendly parameter setting and monitoring.
  • One-Touch Automated Operation simplifies sterilization procedures and reduces operator workload. ➤ One-Touch Automated Operation simplifies sterilization procedures and reduces operator workload.
  • U-Disk Data Storage Function enables convenient storage and transfer of sterilization records. ➤ U-Disk Data Storage Function enables convenient storage and transfer of sterilization records.
  • Precise Hydrogen Peroxide Injection System optimizes sterilant consumption while maintaining sterilization effectiveness. ➤ Precise Hydrogen Peroxide Injection System optimizes sterilant consumption while maintaining sterilization effectiveness.
  • Rectangular Chamber Design maximizes usable loading space and improves instrument arrangement. ➤ Rectangular Chamber Design maximizes usable loading space and improves instrument arrangement.
  • Aluminum Alloy Inner Chamber offers corrosion resistance, excellent thermal conductivity, and uniform chamber conditions. ➤ Aluminum Alloy Inner Chamber offers corrosion resistance, excellent thermal conductivity, and uniform chamber conditions.
  • Real-Time Process Monitoring continuously supervises sterilization parameters throughout the cycle. ➤ Real-Time Process Monitoring continuously supervises sterilization parameters throughout the cycle.
  • Residue-Free Sterilization Process converts hydrogen peroxide into water and oxygen after the cycle. ➤ Residue-Free Sterilization Process converts hydrogen peroxide into water and oxygen after the cycle.

Applications Hydrogen Peroxide Plasma Sterilizer LPP-101

  • Hospitals & Surgical Centers: Suitable for low-temperature sterilization of compatible heat- and moisture-sensitive surgical instruments, endoscopes, and reusable medical devices Hospitals & Surgical Centers
    Suitable for low-temperature sterilization of compatible heat- and moisture-sensitive surgical instruments, endoscopes, and reusable medical devices
  • Endoscopy Units: Supports sterilization of compatible rigid and flexible endoscopes and other delicate instruments that may be unsuitable for high-temperature steam sterilization Endoscopy Units
    Supports sterilization of compatible rigid and flexible endoscopes and other delicate instruments that may be unsuitable for high-temperature steam sterilization
  • Dental Clinics: Suitable for compatible dental handpieces, ophthalmic instruments, laparoscopic tools, and other heat-sensitive reusable instruments Dental Clinics
    Suitable for compatible dental handpieces, ophthalmic instruments, laparoscopic tools, and other heat-sensitive reusable instruments
  • Ophthalmology Departments: Supports low-temperature sterilization of delicate ophthalmic instruments requiring controlled and residue-free processing Ophthalmology Departments
    Supports low-temperature sterilization of delicate ophthalmic instruments requiring controlled and residue-free processing
  • Medical Device Processing: Suitable for sterilization of compatible electrosurgical devices, optical instruments, and complex medical equipment Medical Device Processing
    Suitable for sterilization of compatible electrosurgical devices, optical instruments, and complex medical equipment
  • Pharmaceutical & Research Laboratories: Supports sterilization of compatible heat-sensitive laboratory instruments and devices used in pharmaceutical, biotechnology, and research workflows Pharmaceutical & Research Laboratories
    Supports sterilization of compatible heat-sensitive laboratory instruments and devices used in pharmaceutical, biotechnology, and research workflows
  • Healthcare & CSSD Facilities: Provides automated low-temperature sterilization with process monitoring, safety protection, and USB data storage for routine instrument processing and documentation Healthcare & CSSD Facilities
    Provides automated low-temperature sterilization with process monitoring, safety protection, and USB data storage for routine instrument processing and documentation

Sterilant Cartridge Consumable(3.5ml)
The sterilizer uses a consumable cartridge containing 12 sterilant capsules, with one capsule automatically used per sterilization cycle. Once all 12 capsules have been consumed, the system automatically alerts the user when the cartridge needs to be replaced.