ISO & CE Certified • Global Supply Chain • Comprehensive Warranty
WhatsApp Us!
Request Quote!
0

Laboratory Digestion Unit LMD-301





Description:

Labotemp Laboratory Digestion Unit LMD-301 combines controlled high-temperature sample digestion with dedicated acid gas collection through the Waste Gas Collection Hood, providing a practical solution for laboratories performing acid digestion and sample preparation. The LMD-301 configuration provides 20 sample holes, a 450°C designed temperature, ±1°C temperature control accuracy, approximately 6–15°C/min heating rate, and 4 kW heating power for efficient multi-sample processing. Its 5.5-inch color touchscreen, 9 programmable recipe groups, and 1–999 minute timer support repeatable laboratory workflows, while over-temperature protection helps safeguard the furnace during operation.

During digestion, the paired acid Gas collection hood captures acid mist and waste gases generated from the heated samples and directs them toward a suitable neutralization system before discharge. The hood provides 20 collection ports and 2 extraction openings, with PTFE sealing caps offering high-temperature and acid resistance and a welded stainless steel housing for long-term corrosion resistance. Together, the digestion unit and waste gas collection system provide a more controlled and organized setup for laboratories handling corrosive digestion fumes during sample preparation.

Why Choose Labotemp Laboratory Digestion Unit LMD-301?

✓ 20-Sample Digestion Capacity: Processes multiple samples simultaneously for efficient laboratory workflows.
✓ Precise High-Temperature Control: 450°C designed temperature with ±1°C control accuracy.
✓ Integrated Gas Collection: Collection Hood captures acid mist from the digestion process for controlled exhaust handling.

Specifications:

Laboratory Digestion Unit Specifications
Number of Sample Holes 20 Holes
Aperture Ø43.5 mm
Heating Module Material 6061 Aluminum Alloy
Designed Temperature 450°C
Temperature Control Accuracy ±1°C
Heating Rate ≈6–15°C/min
Control Mode Single-Point Heating
Recipe Management 9 Groups
Timing Shutdown 1–999 Minutes
Power Supply AC 220 V / 50 Hz
Heating Power 4 kW
Dimensions (W × D × H) 542 × 387 × 533 mm
Shipping Size (W × D × H) 690 × 530 × 650 mm
Net Weight 26 kg
Gross Weight 35 kg
Waste Gas Collection Hood Specifications
Collection Port 20
Extraction Opening 2
Dimensions (W × D × H) (Waste Gas Collection Hood) 250 × 150 × 160 mm
Shipping Size (W × D × H) (Waste Gas Collection Hood) 490 × 500 × 470 mm
Net Weight (Waste Gas Collection Hood) 4.2 kg
Gross Weight (Waste Gas Collection Hood ) 6 kg
Collection Hood Material Welded Stainless Steel
Sealing Cap Material High-Temperature and Strong Acid-Resistant PTFE
Features:
    • 9 Programmable Recipes
    • 20-hole digestion configuration supports simultaneous processing of multiple samples.
    • 6061 aluminum alloy heating module provides durable and efficient heat transfer.
    • High-temperature operation up to 450°C supports demanding digestion procedures.
    • ±1°C temperature control accuracy helps maintain consistent digestion conditions.
    • Single-point heating provides controlled and uniform heating across the sample positions.
    • Heating rate of approximately 6–15°C/min supports efficient temperature ramping.
    • 9 programmable recipe groups allow repeatable digestion workflows for different methods.
    • Adjustable 1–999 minute timer supports controlled digestion cycles.
    • 5.5-inch color touchscreen provides convenient parameter setting and monitoring.
    • Over-temperature protection helps safeguard the equipment during operation.
    • Waste gas collection hood provides 20 collection ports for handling digestion fumes.
    • Two extraction openings support connection to an appropriate exhaust or neutralization system.
    • PTFE sealing caps provide resistance to high temperatures and strong acids.
    • Welded stainless steel gas collection hood offers corrosion-resistant construction for digestion environments.
    • Combined furnace and waste gas collection configuration supports more controlled acid digestion workflows.
Applications:

Environmental Sample Digestion:

Supports controlled acid digestion of soil, water, sludge, and other environmental samples before chemical analysis.

Food & Agricultural Testing:

Used for preparing food, feed, crop, and agricultural samples for laboratory analysis and quality testing.

Pharmaceutical Analysis:

Supports controlled digestion and sample preparation procedures in pharmaceutical research and quality control laboratories.

Chemical Laboratories:

Provides repeatable high-temperature digestion for samples requiring controlled heating before instrumental analysis.

Research & Academic Laboratories:

Suitable for analytical research, method development, and laboratory teaching involving multi-sample digestion.

Multi-Sample Laboratory Processing:

Processes multiple samples simultaneously while the connected waste gas collection hood helps manage acid fumes generated during digestion.

Standard Accessories

Waste Gas Collection Hood

Labotemp Scientific

144 E, Midwest Avenue, Casper WY 82601, USA

Website: www.labotemp.com | Email: info@labotemp.com