Request Quote
Scan Whatsapp QR
Request Quote
Scan Whatsapp QR
Labotemp Electric Blast Drying Oven FOV-04 is engineered for large-capacity, precise, and uniform laboratory drying applications. It features a durable 210 L stainless-steel chamber with a wide temperature range from RT+10 °C to 300 °C, ensuring accurate and consistent results. Equipped with an advanced forced-air circulation system and PID temperature control, this oven provides superior heat uniformity and stability, making it ideal for chemical, industrial, and educational laboratories requiring reliable and efficient drying performance
| Temperature Control Range | RT+10°C ~ 300°C |
| Capacity | 210L |
| Power | 3000W |
| Temperature Resolution | 0.1°C |
| Temperature Fluctuation | ±1°C |
| Studio Size | 500 × 600 × 700 mm |
| Overall Dimensions | 670 × 910 × 880 mm |
| Package Size | 720 × 970 × 950 mm |
| Net Weight / Gross Weight | 71 kg / 80 kg |
Used for material testing, sample preparation, component drying under controlled temperature conditions, drying, baking, sterilizing, and heat treatment
Temperature Resolution: 0.1°C
Temperature Fluctuation: ±1°C
Temperature Control Range: RT+10°C ~ 300°C
Studio Size: 350 × 350 × 350 mm
Temperature Resolution: 0.1°C
Temperature Fluctuation: ±1°C
Temperature Control Range: RT+10°C ~ 300°C
Studio Size: 350 × 450 × 450 mm
Temperature Resolution: 0.1°C
Temperature Fluctuation: ±1°C
Temperature Control Range: RT+10°C ~ 300°C
Studio Size: 450 × 550 × 550 mm
Temperature Resolution: 0.1°C
Temperature Fluctuation: ±1°C
Temperature Control Range: RT+10°C ~ 300°C
Studio Size: 500 × 600 × 700 mm
Timer Range: 0–9999 minutes
Temperature Resolution: 0.1°C
Temperature Fluctuation: ±1.0°C
Temperature Distribution Accuracy: ±2.0%
Timer Range: 0–9999 minutes
Temperature Resolution: 0.1°C
Temperature Fluctuation: ±1.0°C
Temperature Distribution Accuracy: ±2.0%
Timer Range: 0–9999 minutes
Temperature Resolution: 0.1°C
Temperature Fluctuation: ±1.0°C
Temperature Distribution Accuracy: ±2.0%
Timer Range: 0–9999 minutes
Temperature Resolution: 0.1°C
Temperature Fluctuation: ±1.0°C
Temperature Distribution Accuracy: ±2.0%
Timer Range: 0–9999 minutes
Temperature Resolution: 0.1°C
Temperature Fluctuation: ±1.0°C
Temperature Distribution Accuracy: ±2.0%
Timer Range: 0–9999 minutes
Temperature Resolution: 0.1°C
Temperature Fluctuation: ±1.0°C
Temperature Distribution Accuracy: ±2.0%
Timer Range: 0–9999 minutes
Temperature Resolution: 0.1°C
Temperature Fluctuation: ±1.0°C
Temperature Distribution Accuracy: ±2.0%
Timer: 0–9999 minutes
Temperature Resolution: 0.1°C
Temperature Fluctuation: ±1.0°C
Temperature Distribution Accuracy: ±3.0%
Timer: 0–9999 minutes
Temperature Resolution: 0.1°C
Temperature Fluctuation: ±1.0°C
Temperature Distribution Accuracy: ±3.0%
Timer: 0–9999 minutes
Temperature Resolution: 0.1°C
Temperature Fluctuation: ±1.0°C
Temperature Distribution Accuracy: ±3.0%
Timer: 0–9999 minutes
Temperature Resolution: 0.1°C
Temperature Fluctuation: ±1.0°C
Temperature Distribution Accuracy: ±3.0%
Timer: 0–9999 minutes
Temperature Resolution: 0.1°C
Temperature Fluctuation: ±1.0°C
Temperature Distribution Accuracy: ±3.0%
Volume (L): 50
Uniformity: 2.50%
Timing: 0–9999 min
Temp Range: RT+20–500°C
Volume (L): 150
Uniformity: 2.50%
Timing: 0–9999 min
Temp Range: RT+20–500°C
Volume (L): 91
Uniformity: 2.50%
Timing: 0–9999 min
Temp Range: RT+20–600°C
Volume (L): 208
Uniformity: 2.50%
Timing: 0–9999 min
Temp Range: RT+20–600°C
Volume (L): 1000
Uniformity: ±3%
Timing: 0–9999 min
Temp Range: RT+10–250°C
Volume (L): 1300
Uniformity: ±3%
Timing: 0–9999 min
Temp Range: RT+10–250°C
Volume (L): 3070
Uniformity: ±3%
Timing: 0–9999 min
Temp Range: RT+10–250°C
Volume (L): 24
Timing: 0–9999 min
Temp Range: RT+10–250°C
Safety: Over-temp alarm
Volume (L): 91
Timing: 0–9999 min
Temp Range: RT+10–250°C
Safety: Over-temp alarm
Volume (L): 52
Timing: 0–9999 min
Temp Range: RT+10–250°C
Safety: Over-temp alarm