Vacuum Furnace FVA-19

Labotemp Vacuum Furnace FVA-19 is a horizontal, front-loading, single-chamber furnace designed for high-temperature vacuum heat treatment of aerospace alloy components, precision parts and tool steel. With a maximum working temperature of 1315°C, an effective heating zone of 305 × 305 × 457 mm and a maximum loading capacity of 120 kg including tooling, this system supports vacuum quenching, annealing, tempering, solution treatment and ageing processes. Its vacuum system achieves an ultimate vacuum of 6.7 × 10⁻⁴ Pa under specified empty-furnace conditions.

Featuring molybdenum heating elements, composite metal insulation and a double-layer water-cooled stainless steel body, FVA-19 combines controlled heating with vacuum and inert gas cooling. Nitrogen or argon circulation operates at adjustable gas pressure from 0 to 2 bar absolute through a closed-loop cooling system. Temperature control accuracy reaches ±1°C, with specified temperature uniformity of ±5°C. PLC and industrial computer controls support automatic and manual operation, storage for at least 999 process recipes, multilingual HMI, paperless recording and remote monitoring. Integrated safety interlocks and alarms monitor temperature, vacuum, pressure, cooling water and electrical conditions.

Why Choose Labotemp Vacuum Furnace FVA-19?

✓ High-Temperature Processing: Maximum working temperature of 1315°C.
✓ High-Vacuum Performance: Ultimate vacuum of 6.7 × 10⁻⁴ Pa under specified conditions.
✓ Controlled Gas Cooling: Adjustable nitrogen or argon cooling pressure.

Technical data · FVA-19

Complete Specifications

Vacuum Furnace FVA-19
No.SpecificationValue
General Information
1Product TypeVacuum Furnace
2ModelFVA-19
3Furnace StructureHorizontal, front-loading, single-chamber
4Furnace Body MaterialSS304 stainless steel
5Effective Heating Zone305 × 305 × 457 mm
6Maximum Loading Capacity120 kg, including tooling
Temperature and Heating
7Maximum Working Temperature1315°C
8Maximum Design Temperature1371°C
9Working Temperature Range538°C–1315°C
10Temperature Control Accuracy≤ ±1°C
11Temperature Uniformity≤ ±5°C
12Heating TimeLess than 60 minutes from room temperature to 1100°C, without loading
13Heating Power80 kW
Vacuum System
14Working Vacuum6.7 × 10⁻³ Pa
15Partial Pressure Range10–2000 Pa
16Vacuum Pump-Down Time≤ 20 minutes, without loading
17Mechanical Roughing Pump300 Nm³/h, 5.5 kW
18High-Vacuum Diffusion Pump12,000 L/s, 8 kW
19Holding Pump40 Nm³/h, 1.5 kW
Cooling System
20Cooling GasNitrogen or argon
21Cooling Motor Power7.5 kW
Electrical Requirements
22Power Supply460 V
23Phase3-phase
24Frequency60 Hz
25Total Installed Peak Power100 kW
26Heating Transformer80 kVA
Safety Features
27Over-Temperature ProtectionYes
28Vacuum InterlockYes
29Door Locking ProtectionYes
30Emergency StopYes
31Alarm SystemAudible and visual
What's included

Features

  1. 1
    Maximum Temperature 1315°C
  2. 2
    Horizontal Front-Loading Design
  3. 3
    Single-Chamber Construction
  4. 4
    Molybdenum Heating Elements
  5. 5
    Composite Metal Thermal Insulation
  6. 6
    Double-Layer Water-Cooled Furnace Body
  7. 7
    Integrated Vacuum Pumping System
  8. 8
    Closed-Loop Gas Cooling
  9. 9
    Copper Heat Exchanger
  10. 10
    360° Gas Distribution Nozzles
  11. 11
    PLC and Industrial Computer Control
  12. 12
    Automatic and Manual Operation
  13. 13
    Multilingual HMI
  14. 14
    Remote Monitoring and Diagnosis
  15. 15
    Electric Loading Trolley
  16. 16
    Safety Interlocks and Alarm System
Where it's used

Applications

Vacuum Quenching: Heat treatment of suitable alloy components followed by controlled inert gas cooling.

Vacuum Annealing: Controlled annealing of metallic materials under vacuum conditions.

Vacuum Tempering: Thermal treatment of suitable tool steel and metal components.

Solution Treatment: High-temperature solution treatment of compatible alloy components.

Ageing Treatment: Controlled thermal ageing of suitable metal alloys.

Aerospace Component Processing: Vacuum heat treatment of suitable aerospace alloy components.

Vacuum Furnace FVA-19

LET'S EQUIP
YOUR LABORATORY

View product online

+1 581 465 8405

www.labotemp.com · info@labotemp.com

144 E, Midwest Avenue, Casper WY 82601, USA

More about this product

Standard Accessories

  1. 1
    Electric Loading Trolley
  2. 2
    Loading Basket
  3. 3
    Vacuum Pump Unit
  4. 4
    Heating Transformer
  5. 5
    Air Cooler
More about this product

Optional Accessories

  1. 1
    Mo-La Heating Elements
  2. 2
    Gas Buffer Tank (3 m³)