ISO & CE Certified • Global Supply Chain • Comprehensive Warranty
WhatsApp Us!
Request Quote!
0
Flame Photometer LFP-101
Flame Photometer

Flame Photometer LFP-101

Labotemp Flame Photometer LFP-101 is a compact analytical instrument designed for flame photometry and direct measurement of potassium (K), sodium (Na), lithium (Li), and calcium (Ca) in routine laboratory analysis. Its 7-inch colour capacitive touch LCD provides an intuitive interface for displaying concentration values or light intensity, while the four-channel configuration supports efficient multi-element testing. With a reading range of 0.000–999.9 / 0–65535, response time of less than 8 seconds, and repeatability of ≤3%, the flame photometer provides consistent results for clinical, pharmaceutical, chemical, food, agricultural, and research applications.

Designed for dependable everyday operation, the LFP-101 combines straightforward touch-screen control with practical data-management and safety features. Automatic correlation-coefficient calculation, USB data export and communication, optional computer software, Bluetooth printer connectivity, and cloud-based interconnection simplify result recording and laboratory documentation. A fire-extinguishing protection device and gas-leakage alarm provide additional operational protection. Its compact design, low sample consumption, and reliable analytical performance make it a practical flame photometer for routine electrolyte and elemental analysis.

Why Choose Labotemp Flame Photometer LFP-101?

✓ Multi-Element Analysis: Direct measurement of potassium, sodium, lithium, and calcium.
✓ Fast Results: Response time of less than 8 seconds supports efficient routine testing.
✓ Reliable Measurement: Repeatability of ≤3% helps maintain consistent analytical performance.

$5581
Datasheet

Specifications Flame Photometer LFP-101

General Specifications

Measurement Elements : K, Na, Li, Ca

Measurement Elements
K, Na, Li, Ca

Number of Channels : 4

Number of Channels
4

Reading Range : 0.000–999.9 / 0–65535

Reading Range
0.000–999.9 / 0–65535

Measurement Range : 0–100 ppm

Measurement Range
0–100 ppm

Display : 7-inch Colour Capacitive Touch LCD

Display
7-inch Colour Capacitive Touch LCD

Display Results : Concentration Value / Light Intensity

Display Results
Concentration Value / Light Intensity

Linearity : ≥0.999

Linearity
≥0.999

Repeatability : ≤3%

Repeatability
≤3%

Response Time : <8 s

Response Time
<8 s
Analytical Performance

Sensitivity / Detection Limit : K: ≤0.004 mmol/L; Na: ≤0.008 mmol/L

Sensitivity / Detection Limit
K: ≤0.004 mmol/L; Na: ≤0.008 mmol/L

Accuracy (Linearity Error) : K: ≤0.005 mmol/L; Na: ≤0.03 mmol/L

Accuracy (Linearity Error)
K: ≤0.005 mmol/L; Na: ≤0.03 mmol/L

Li Detection Limit : ≤0.015 mmol/L

Li Detection Limit
≤0.015 mmol/L

Ca Detection Limit : ≤0.050 mmol/L

Ca Detection Limit
≤0.050 mmol/L

Li Accuracy (Linearity Error) : ≤0.021 mmol/L

Li Accuracy (Linearity Error)
≤0.021 mmol/L

Ca Accuracy (Linearity Error) : ≤0.075 mmol/L

Ca Accuracy (Linearity Error)
≤0.075 mmol/L

Stability : Relative change ≤3% per minute; total measurement variation ≤15%

Stability
Relative change ≤3% per minute; total measurement variation ≤15%

Calibration : Multi-point calibration (≥3 points)

Calibration
Multi-point calibration (≥3 points)

Correlation Coefficient : Automatic calculation

Correlation Coefficient
Automatic calculation
Operation

Flame : LPG / Propane / Butane

Flame
LPG / Propane / Butane

Ignition : Automatic ignition

Ignition
Automatic ignition

Sample Aspiration : Continuous sample aspiration

Sample Aspiration
Continuous sample aspiration

Small Suction Spray Amount : <6 mL/min

Small Suction Spray Amount
<6 mL/min

Interference Filters : Yes

Interference Filters
Yes

Temperature / Environment : Room laboratory conditions

Temperature / Environment
Room laboratory conditions
Safety

Flame Safety : Flame failure detection

Flame Safety
Flame failure detection

Gas Control : Gas control system

Gas Control
Gas control system

Gas Leakage Protection : Gas leakage alarm

Gas Leakage Protection
Gas leakage alarm

Fire Protection : Fire-extinguishing protection device

Fire Protection
Fire-extinguishing protection device
Connectivity & Data Management

USB Port : Yes

USB Port
Yes

Communication : USB / RS232

Communication
USB / RS232

Computer Software : Optional

Computer Software
Optional

Printer : Standard

Printer
Standard

Printer Type : Bluetooth printer

Printer Type
Bluetooth printer

Cloud-Based Interconnection : Yes

Cloud-Based Interconnection
Yes
Electrical Specifications

Power Supply : AC 220–240 V, 50 Hz

Power Supply
AC 220–240 V, 50 Hz

Rated Power : 400 W

Rated Power
400 W
Physical & Packaging Specifications

Package Size : 770 × 400 × 540 mm

Package Size
770 × 400 × 540 mm

Net Weight : 20 kg

Net Weight
20 kg

Gross Weight : 33 kg

Gross Weight
33 kg

Features Flame Photometer LFP-101

  • 4-Element Flame Photometry ➤ 4-Element Flame Photometry
  • 7-inch Colour Capacitive Touch LCD for intuitive operation. ➤ 7-inch Colour Capacitive Touch LCD for intuitive operation.
  • Four-Channel Element Analysis for K, Na, Li, and Ca measurement. ➤ Four-Channel Element Analysis for K, Na, Li, and Ca measurement.
  • Direct concentration measurement with light-intensity display. ➤ Direct concentration measurement with light-intensity display.
  • Fast Response Time of &lt;8 Seconds for efficient routine analysis. ➤ Fast Response Time of <8 Seconds for efficient routine analysis.
  • Low Sample Consumption of &lt;6 mL/min. ➤ Low Sample Consumption of <6 mL/min.
  • ≤3% Repeatability for consistent analytical results. ➤ ≤3% Repeatability for consistent analytical results.
  • Automatic Correlation Coefficient Calculation. ➤ Automatic Correlation Coefficient Calculation.
  • USB port for data export and instrument communication. ➤ USB port for data export and instrument communication.
  • Optional computer software for extended data management. ➤ Optional computer software for extended data management.
  • Bluetooth Printer Connectivity for convenient result documentation. ➤ Bluetooth Printer Connectivity for convenient result documentation.
  • Cloud-based interconnection for connected laboratory workflows. ➤ Cloud-based interconnection for connected laboratory workflows.
  • Fire-extinguishing protection device for enhanced operational safety. ➤ Fire-extinguishing protection device for enhanced operational safety.
  • Gas-leakage alarm for additional laboratory protection. ➤ Gas-leakage alarm for additional laboratory protection.
  • Compact design suitable for routine laboratory environments. ➤ Compact design suitable for routine laboratory environments.
  • Simple touch-screen operation for efficient elemental analysis. ➤ Simple touch-screen operation for efficient elemental analysis.

Applications Flame Photometer LFP-101

  • Clinical &amp; Medical Laboratories:Suitable for routine determination of sodium, potassium, calcium, lithium, and other measurable elements in laboratory analysis Clinical & Medical Laboratories
    Suitable for routine determination of sodium, potassium, calcium, lithium, and other measurable elements in laboratory analysis
  • Pharmaceutical Laboratories:Supports elemental analysis and quality-control workflows involving sodium, potassium, lithium, calcium, and barium Pharmaceutical Laboratories
    Supports elemental analysis and quality-control workflows involving sodium, potassium, lithium, calcium, and barium
  • Chemical &amp; Research Laboratories:Useful for routine elemental concentration measurement and analytical research Chemical & Research Laboratories
    Useful for routine elemental concentration measurement and analytical research
  • Food &amp; Beverage Testing:Supports mineral and elemental analysis in food, beverage, and related quality-control applications Food & Beverage Testing
    Supports mineral and elemental analysis in food, beverage, and related quality-control applications
  • Agricultural Laboratories:Suitable for elemental analysis of agricultural and related laboratory samples Agricultural Laboratories
    Suitable for elemental analysis of agricultural and related laboratory samples
  • Environmental Testing:Can be used for routine analytical workflows requiring flame-based determination of measurable elements Environmental Testing
    Can be used for routine analytical workflows requiring flame-based determination of measurable elements

Standard Accessories

  • Compressor ➤ Compressor
  • Gas Regulator ➤ Gas Regulator
  • Tubing ➤ Tubing