Labotemp Semi-Automatic Chemistry Analyzer LCA-101 is a reliable and efficient clinical chemistry analyzer designed for routine diagnostic testing in hospitals, laboratories, and research facilities. Supporting multiple analysis methods including end-point, fixed-time, and kinetic testing, this versatile chemistry analyzer ensures accurate evaluation of serum, plasma, urine, and other biological samples. With a 7-inch LCD touch screen, intuitive interface, and storage capacity for up to 20,000 results, it simplifies daily workflows while maintaining consistency in reporting. The integrated incubator with controlled temperature settings ensures stable reaction conditions for precise and repeatable test outcomes.
Built for dependable laboratory performance, the system features a flow-through cuvette design for efficient sample handling and a multi-wavelength optical system (340–630 nm) for accurate measurements. The built-in thermal printer enables instant result documentation, while RS-232 and USB connectivity support data management and integration. Designed with energy-efficient operation and robust internal components, this analyzer ensures long-term reliability with minimal maintenance. Its compact footprint and user-friendly automation make it suitable for both small labs and high-throughput diagnostic environments.
Why Choose Labotemp Semi-Automatic Chemistry Analyzer?
✓ Accurate multi-method testing: Supports end-point, kinetic, and fixed-time analysis
✓ Stable temperature control: Ensures reliable reaction conditions
✓ User-friendly operation: Touchscreen interface with large data storage
|
Incubator Temperature : R.T., 25°C, 30°C, 37°C (four options) Incubator Temperature |
R.T., 25°C, 30°C, 37°C (four options) |
|
Cuvette : Flow-through direct-reading cuvette Cuvette |
Flow-through direct-reading cuvette |
|
Wavelength : 340 / 405 / 450 / 510 / 546 / 578 / 630 nm, plus 2 open filter positions Wavelength |
340 / 405 / 450 / 510 / 546 / 578 / 630 nm, plus 2 open filter positions |
|
Wavelength Accuracy : ±2 nm Wavelength Accuracy |
±2 nm |
|
Screen : 7.0 inch LCD touch screen Screen |
7.0 inch LCD touch screen |
|
Language : English, French, Spanish (customizable) Language |
English, French, Spanish (customizable) |
|
Printer : Built-in thermal printer Printer |
Built-in thermal printer |
|
Interface : RS-232, USB Interface |
RS-232, USB |
|
Power Consumption : 150 VA Power Consumption |
150 VA |
|
Power Supply : AC 110/220V ±10%, 50/60 Hz Power Supply |
AC 110/220V ±10%, 50/60 Hz |
|
External Size (W×D×H) : 400 × 410 × 190 mm External Size (W×D×H) |
400 × 410 × 190 mm |
|
Packing Size (W×D×H) : 520 × 490 × 330 mm Packing Size (W×D×H) |
520 × 490 × 330 mm |
|
Net Weight : 9 kg Net Weight |
9 kg |
|
Gross Weight : 12 kg Gross Weight |
12 kg |
|
Incubating Positions : 20 incubating positions Incubating Positions |
20 incubating positions |
|
Sample Type : Serum, Plasma, Urine, Cerebrospinal fluid, etc Sample Type |
Serum, Plasma, Urine, Cerebrospinal fluid, etc |
|
Analytical Method : End point method, Fixed time method (two-point method), Dynamic method (rate method) Analytical Method |
End point method, Fixed time method (two-point method), Dynamic method (rate method) |
User-friendly Control
➤ User-friendly ControlAdvanced optical system with stable light source ensures consistent absorbance readings across multiple wavelengths.
➤ Advanced optical system with stable light source ensures consistent absorbance readings across multiple wavelengths.Multi-mode calibration capability including linear and non-linear curve fitting for improved test accuracy.
➤ Multi-mode calibration capability including linear and non-linear curve fitting for improved test accuracy.Real-time reaction curve display enables better monitoring and validation of assay performance.
➤ Real-time reaction curve display enables better monitoring and validation of assay performance.User-defined test parameters allow customization for specialized assays and reagents.
➤ User-defined test parameters allow customization for specialized assays and reagents.Automatic blank correction function enhances measurement reliability and reduces manual errors.
➤ Automatic blank correction function enhances measurement reliability and reduces manual errors.Robust internal quality control (QC) program supports daily validation and compliance workflows.
➤ Robust internal quality control (QC) program supports daily validation and compliance workflows.Low reagent consumption design optimizes operational cost efficiency for routine testing.
➤ Low reagent consumption design optimizes operational cost efficiency for routine testing.Compact bench-top structure with vibration-resistant design ensures stable performance during operation.
➤ Compact bench-top structure with vibration-resistant design ensures stable performance during operation.Quick warm-up system minimizes waiting time and improves overall lab productivity.
➤ Quick warm-up system minimizes waiting time and improves overall lab productivity.LCA-101 is used for routine and semi-quantitative biochemical assays in clinical labs, including enzyme activity, glucose, lipid, and metabolite analysis
➤ LCA-101 is used for routine and semi-quantitative biochemical assays in clinical labs, including enzyme activity, glucose, lipid, and metabolite analysisSupports multi-wavelength photometric testing and temperature-controlled reactions, making it suitable for hospital diagnostics, research labs, and quality control in pharmaceutical and academic settings
➤ Supports multi-wavelength photometric testing and temperature-controlled reactions, making it suitable for hospital diagnostics, research labs, and quality control in pharmaceutical and academic settings
LCA-101 is used for routine and semi-quantitative biochemical assays in clinical labs, including enzyme activity, glucose, lipid, and metabolite analysis. Supports multi-wavelength photometric testing and temperature-controlled reactions, making it suitable for hospital diagnostics, research labs, and quality control in pharmaceutical and academic settings.