Description:

Labotemp Fully Automated Chemistry Analyzer LCA-201 is a high-throughput chemistry analyzer machine designed for routine clinical chemistry testing in diagnostic and laboratory settings. The system supports serum, plasma, urine, cerebrospinal fluid and whole blood for HbA1c testing, with a biochemical testing speed of up to 360 T/H and optional ISE throughput of up to 480 T/H. It can simultaneously analyze up to 103 projects, supporting a broad testing workload including liver and renal function, lipid profile, cardiovascular markers, glucose metabolism, pancreatic function, special proteins, rheumatic testing, anemia-related parameters and inorganic ions.

Designed for consistent and repeatable analysis, the clinical chemistry analyzer maintains the reaction vessel at 37±0.1°C and provides continuous reagent refrigeration at 2–12°C. Its optical system uses 12 detection wavelengths from 340 to 800 nm, while liquid-level detection, volume tracking, 3D anti-collision and intelligent full-needle cleaning support reliable sample handling. Sample volumes range from 2–35 μL, with dilution testing from 3 to 100 times, and sample-needle cross-contamination is specified at ≤0.05%. Automated reaction-cup cleaning, optimized mixing and a water consumption of ≤6.5 L/h further support practical long-term laboratory operation.

Why Choose Labotemp Fully Automated Chemistry Analyzer LCA-201?

✓ High Testing Throughput: Up to 360 T/H biochemical testing with optional ISE capability up to 480 T/H.
✓ Stable Reaction Conditions: Maintains reaction temperature at 37±0.1°C with refrigerated reagents at 2–12°C.
✓ Reliable Sample Handling: Liquid-level detection, volume tracking, 3D anti-collision and full-needle cleaning help support consistent testing.

Specifications:

General Specifications
Product Type Fully Automated Chemistry Analyzer
Biochemical Module Throughput Maximum 360 T/H
Simultaneous Analysis Projects Up to 103
Sample Types Serum, Plasma, Urine, Cerebrospinal Fluid, Whole Blood (HbA1c)
Sample Unit
Sample Positions 50–100
Sample Volume 2–35 μL
Sample Volume Increment 0.1 μL
Sample Addition Technology Liquid Level Detection, Volume Tracking, 3D Anti-Collision
Needle Blockage Detection Optional
Needle Cleaning Intelligent Full-Needle 3D Cleaning
Sample Dilution Supported
Dilution Factor 3–100 Times
Sample Needle Cross-Contamination Rate ≤0.05%
Reagent & Reaction Unit
Reagent Positions 50–100
Reagent Refrigeration 2–12°C, Continuous Refrigeration for 24 Hours
Reagent Volume 10–200 μL
Reagent Volume Increment 0.5 μL
Reaction Cups 80 Special Optical Plastic Colorimetric Cups
Reaction Temperature 37±0.1°C
Reaction Liquid Volume 100–360 μL
Reaction Cup Cleaning Cleaning Agent and Warm Water
Optical System
Illuminant 12V, 20W Long-Life Halogen Tungsten Lamp
Lamp Service Life 2000 H
Beam Splitting Method Post-Holographic Concave Grating Beam Splitting System
Detection Wavelengths 340 nm, 380 nm, 412 nm, 450 nm, 505 nm, 546 nm, 570 nm, 605 nm, 660 nm, 700 nm, 740 nm, 800 nm
Number of Detection Wavelengths 12
Absorbance Range 0–3.5 A
Stray Light Absorbance should be not less than 4.9
Electrical, Environmental & Physical Specifications
Power Supply 100V–240V, 50/60 Hz
Ambient Temperature 15–30°C
Operating Altitude -400 m–2000 m
Water Consumption ≤6.5 L/h
Main Unit Dimensions (L × W × H) 860 × 660 × 920 mm
Features:
    • 360 T/H Max Throughput
    • Supports simultaneous analysis of up to 103 projects
    • Supports serum, plasma, urine, cerebrospinal fluid and whole blood for HbA1c testing
    • 50–100 sample positions for flexible sample loading
    • 2–35 μL sample volume with 0.1 μL increments
    • Intelligent liquid-level detection for reliable sample aspiration
    • Real-time sample volume tracking
    • 3D anti-collision technology helps protect the sampling system
    • Optional needle blockage detection
    • Intelligent full-needle 3D cleaning system
    • Sample dilution testing with adjustable 3–100 times dilution factor
    • Sample needle cross-contamination rate of ≤0.05%
    • 50–100 reagent positions
    • Continuous reagent refrigeration at 2–12°C for up to 24 hours
    • 10–200 μL reagent volume with 0.5 μL increments
    • 80 special optical plastic colorimetric reaction cups
    • Stable reaction temperature of 37±0.1°C
    • Reaction liquid volume of 100–360 μL
    • Automated reaction-cup cleaning using cleaning agent and warm water
    • 12 detection wavelengths from 340–800 nm
    • Long-life 12V, 20W halogen tungsten lamp with 2000-hour service life
    • Post-holographic concave grating beam-splitting optical system
    • Absorbance range of 0–3.5 A
    • High-precision optical detection for biochemical analysis
    • High-precision syringe assembly for sample addition
    • Polished stirring rod designed for stable and reliable mixing
    • Intelligent cleaning system designed to reduce cross-contamination
    • Automatic cleaning of reaction cups using multiple cleaning steps
    • Support for cross-contamination treatment procedures for different sample types
    • Supports customized testing parameters according to laboratory requirements
    • Traceability testing system for reference-based biochemical measurement
    • Patient information entry and report-printing functions
    • Multiple report formats and quality-control interfaces
    • Whole-blood HbA1c testing with automated red-blood-cell processing
    • Smart sampling technology for HbA1c sample preparation
    • Supports NGSP or IFCC HbA1c result output
    • Broad testing menu covering lipid, liver, renal, cardiovascular, glucose metabolism, pancreatic, special protein, rheumatic, anemia and inorganic-ion testing
    • Water consumption of ≤6.5 L/h for practical laboratory operation
Applications:

Clinical Chemistry Testing: Supports routine biochemical testing of patient samples including serum, plasma, urine and cerebrospinal fluid.

Liver Function Analysis: Used for biochemical assessment of liver-related parameters such as ALT, AST, ALP, bilirubin and albumin.

Renal Function Testing: Supports analysis of kidney-related parameters including urea, creatinine, cystatin C and microalbumin.

Lipid Profile Testing: Used for measurement of lipid and lipoprotein parameters including total cholesterol, triglycerides, HDL-C and LDL-C.

Cardiovascular Testing: Supports biochemical testing of cardiovascular-related markers such as CK, CK-MB, LDH, hs-CRP and related parameters.

Glucose Metabolism Testing: Used for analysis of glucose metabolism parameters including glucose, HbA1c and β-HB.

Pancreatic Function Testing: Supports biochemical analysis of pancreatic-related parameters including α-amylase and lipase.

Special Protein Testing: Used for analysis of special proteins including C3, C4, IgG, IgA and IgM.

Rheumatic Testing: Supports testing of rheumatic-related markers including CRP, ASO II and RF II.

Anemia-Related Testing: Used for analysis of iron and related parameters including Fe, ferritin, transferrin and UIBC.

Inorganic Ion Testing: Supports analysis of inorganic ions including calcium, phosphorus, magnesium, CO₂, sodium, potassium and chloride.

Whole-Blood HbA1c Testing: Supports automated HbA1c analysis from whole-blood samples with direct NGSP or IFCC result output. 

Optional Accessories

  • Optional module with maximum throughput of 480 T/H.
  • Needle Blockage Detection- Optional sample needle blockage detection function.