ISO & CE Certified • Global Supply Chain • Comprehensive Warranty
WhatsApp Us!
Request Quote!
0
Cassette Autoclave PTA-06
cassette autoclave

Cassette Autoclave PTA-06

Labotemp Cassette Autoclave PTA-06 is a compact steam sterilizer designed for rapid sterilization of small medical and dental instruments. The cassette-based system generates steam from distilled water and directs it through a sealed cassette, helping remove trapped air before sterilization. With selectable steam temperatures from 115–135°C and sterilization times from 4–99 minutes, it provides flexible processing for different instrument requirements. Its compact format makes it practical where fast instrument turnover and limited workspace are important.

Designed for quick turnaround in busy clinical environments, the PTA-06 can complete its shortest sterilization cycle in approximately 6–7 minutes, reducing the time instruments remain exposed to high-temperature steam. Its digital display, selectable sterilization programs, automatic monitoring and warning functions support straightforward operation, while alerts for low water, low temperature and low pressure improve operational safety. The system also includes a drying function, while the cassette serves as a convenient container for handling, temporary storage and transport of sterilized instruments.

Why Choose Labotemp Cassette Autoclave PTA-06?

✓ Rapid Sterilization: Shortest cycle takes approximately 6–7 minutes.
✓ Flexible Temperature Control: Selectable steam temperature from 115–135°C.
✓ Safety Monitoring: Provides alerts for low water, low temperature and low pressure conditions.

$10008
Datasheet

Specifications Cassette Autoclave PTA-06

General Specifications

Chamber Volume : 5.2 L

Chamber Volume
5.2 L

Reservoir Volume : 3.4 L

Reservoir Volume
3.4 L

Machine Dimensions : 580 × 460 × 190 mm

Machine Dimensions
580 × 460 × 190 mm

Net Weight : 56.5 kg

Net Weight
56.5 kg

Gross Weight : 57 kg

Gross Weight
57 kg

Packaging Dimensions : 70 × 58 × 60 cm

Packaging Dimensions
70 × 58 × 60 cm
Cassette Specifications

Cassette External Size : 480 × 196 × 80 mm

Cassette External Size
480 × 196 × 80 mm

Cassette Internal Size : 380 × 180 × 78 mm

Cassette Internal Size
380 × 180 × 78 mm

Filter : 0.22 micron living thing filter

Filter
0.22 micron living thing filter
Sterilization Parameters

Steam Temperature : 115–135°C (Selectable)

Steam Temperature
115–135°C (Selectable)

Sterilization Temperature : 115–135°C

Sterilization Temperature
115–135°C

Sterilization Time : 4–99 min

Sterilization Time
4–99 min

Drying Time : 0–99 min

Drying Time
0–99 min

Shortest Sterilization Cycle : 6–7 minutes

Shortest Sterilization Cycle
6–7 minutes
Electrical Specifications

Electrical Rating : AC220V ±10%

Electrical Rating
AC220V ±10%

Frequency : 50Hz ±1Hz

Frequency
50Hz ±1Hz

Current : 6 A

Current
6 A

Maximum Power : 1.3 kVA

Maximum Power
1.3 kVA

Features Cassette Autoclave PTA-06

  • Rapid 6–7 Minute Cycle ➤ Rapid 6–7 Minute Cycle
  • Three Sterilization Programs – Dedicated programs for appliance, package appliance and nonmetal appliance sterilization. ➤ Three Sterilization Programs – Dedicated programs for appliance, package appliance and nonmetal appliance sterilization.
  • Selectable Steam Temperature – Temperature selection from 115–135°C according to the selected cycle. ➤ Selectable Steam Temperature – Temperature selection from 115–135°C according to the selected cycle.
  • Digital Operation – Digital display and program buttons for convenient control and cycle monitoring. ➤ Digital Operation – Digital display and program buttons for convenient control and cycle monitoring.
  • Distilled Water Operation – Uses distilled water for steam generation. ➤ Distilled Water Operation – Uses distilled water for steam generation.
  • Built-In Drying Function – Provides drying after sterilization for convenient instrument handling. ➤ Built-In Drying Function – Provides drying after sterilization for convenient instrument handling.
  • Low Water Protection – Detects insufficient water and stops sterilization with an alarm. ➤ Low Water Protection – Detects insufficient water and stops sterilization with an alarm.
  • Low Temperature Protection – Alerts the operator and stops sterilization when the required temperature is not achieved. ➤ Low Temperature Protection – Alerts the operator and stops sterilization when the required temperature is not achieved.
  • Low Pressure Protection – Provides an alarm and stops sterilization under low-pressure conditions. ➤ Low Pressure Protection – Provides an alarm and stops sterilization under low-pressure conditions.
  • Cassette-Based Sterilization – Keeps instruments contained during sterilization and handling. ➤ Cassette-Based Sterilization – Keeps instruments contained during sterilization and handling.
  • Rapid Steam Penetration – Directs steam through the cassette to support effective sterilization. ➤ Rapid Steam Penetration – Directs steam through the cassette to support effective sterilization.
  • Compact Design – Suitable for dental clinics, ENT departments and other clinical areas with limited space. ➤ Compact Design – Suitable for dental clinics, ENT departments and other clinical areas with limited space.
  • Instrument Handling Convenience – Cassette supports temporary storage and transport of sterilized instruments. ➤ Instrument Handling Convenience – Cassette supports temporary storage and transport of sterilized instruments.
  • Adjustable Cycle Duration – Sterilization and drying times can be selected according to processing requirements. ➤ Adjustable Cycle Duration – Sterilization and drying times can be selected according to processing requirements.

Applications Cassette Autoclave PTA-06

  • Dental Instrument Sterilization: Suitable for rapid sterilization of small dental instruments requiring efficient steam processing Dental Instrument Sterilization
    Suitable for rapid sterilization of small dental instruments requiring efficient steam processing
  • Medical Instrument Sterilization: Used for sterilizing heat- and moisture-resistant medical instruments in clinical settings Medical Instrument Sterilization
    Used for sterilizing heat- and moisture-resistant medical instruments in clinical settings
  • ENT Instrument Sterilization: Supports rapid sterilization of suitable ENT instruments between procedures ENT Instrument Sterilization
    Supports rapid sterilization of suitable ENT instruments between procedures
  • Gynecology Instrument Sterilization: Suitable for steam sterilization of compatible gynecological instruments Gynecology Instrument Sterilization
    Suitable for steam sterilization of compatible gynecological instruments
  • Small Clinical Practices: Provides compact, rapid sterilization for clinics requiring frequent instrument turnaround Small Clinical Practices
    Provides compact, rapid sterilization for clinics requiring frequent instrument turnaround