Labotemp Automatic Sample Processing System LSP-101 is a modular laboratory automation platform designed to streamline sample addition, reagent dispensing, shaking, incubation and microplate washing. It supports 96-well sample processing, up to 18 reagent positions and a 4-channel sampling system, with liquid-level and clot detection for controlled sample handling. The system is suitable for workflows involving ELISA, luminescence assays, blood typing, antibody screening, PCR, DNA and other laboratory tests, helping laboratories improve processing consistency while reducing repetitive manual operations.
The system combines independent or integrated processing modules to improve workflow efficiency and reduce repetitive manual handling. Its programmable incubation range of 30–75°C, adjustable shaking and washing parameters, disposable-tip sampling and automated process monitoring support consistent laboratory operation. An optional Microplate Reader/Washer-Reader can be added for plate-based measurement, offering 340–750 nm detection, ±1% accuracy, 0.001 OD resolution, optional fluorescence, integrated shaking and standard-curve quantification, providing a more complete automated workflow for plate-based laboratory testing.
Why Choose Labotemp Automatic Sample Processing System LSP-101?
✓ Integrated Automation: Combines sample addition, incubation, shaking and washing in one platform.
✓ Reliable Sample Handling: Liquid-level and clot detection with disposable tips helps reduce handling errors and contamination.
✓ Optional Plate Reading: Microplate Reader/Washer-Reader expands the system for ELISA and other plate-based testing workflows.
| General Specifications | |
|
Sampling Mechanical Arm : 1 arm with 4 channels Sampling Mechanical Arm |
1 arm with 4 channels |
|
Mechanical Grasping Arm : 1 arm; can grab micro plate, test tube, kit, and other items Mechanical Grasping Arm |
1 arm; can grab micro plate, test tube, kit, and other items |
|
Grasping Weight : Up to 400 g Grasping Weight |
Up to 400 g |
|
Sample Location : 96 wells Sample Location |
96 wells |
|
Reagent Location : Up to 18 kinds of reagents can be placed simultaneously Reagent Location |
Up to 18 kinds of reagents can be placed simultaneously |
|
Scanner : Internal scanner; can read more than 20 kinds of barcodes Scanner |
Internal scanner; can read more than 20 kinds of barcodes |
|
Management Modules : Sample management, reagent management, quality control, standard product management Management Modules |
Sample management, reagent management, quality control, standard product management |
|
Process Monitoring : Dynamic monitoring of the working process Process Monitoring |
Dynamic monitoring of the working process |
|
Power-On Self-Check : Initialization and automatic saving of result logs Power-On Self-Check |
Initialization and automatic saving of result logs |
|
Communication Protocol : CAN communication bus Communication Protocol |
CAN communication bus |
|
Dimensions : 1140 mm × 727 mm × 950 mm Dimensions |
1140 mm × 727 mm × 950 mm |
|
Net Weight : 130 kg Net Weight |
130 kg |
| Sample Addition & Handling | |
|
Sample Channels : 4 channels Sample Channels |
4 channels |
|
Sample Channel Spacing : Minimum 9 mm; maximum 350 mm Sample Channel Spacing |
Minimum 9 mm; maximum 350 mm |
|
Sample Module : Single-board sample adding; supports multiple-board splicing function or multiple-board parallel sample adding Sample Module |
Single-board sample adding; supports multiple-board splicing function or multiple-board parallel sample adding |
|
Liquid Surface Detection : Pressure-sensing detection with liquid surface detection and clot detection Liquid Surface Detection |
Pressure-sensing detection with liquid surface detection and clot detection |
|
Alarm Function : Available Alarm Function |
Available |
|
Sample Volume : Minimum 10 μL; maximum 1000 μL Sample Volume |
Minimum 10 μL; maximum 1000 μL |
|
Sample Volume Increment : 5 μL Sample Volume Increment |
5 μL |
|
Safety Protection : Using disposable tips, no cross contamination Safety Protection |
Using disposable tips, no cross contamination |
|
Accuracy at 100 μL : CV <1% Accuracy at 100 μL |
CV <1% |
|
Deviation at 100 μL : ±2.0% Deviation at 100 μL |
±2.0% |
|
Accuracy at 1000 μL : CV <0.5% Accuracy at 1000 μL |
CV <0.5% |
|
Deviation at 1000 μL : ±1.0% Deviation at 1000 μL |
±1.0% |
| Sampling & Reagent Allocation | |
|
Specimen Allocation : 10 min./96 wells Specimen Allocation |
10 min./96 wells |
|
Reagent Allocation : 3 min./96 wells Reagent Allocation |
3 min./96 wells |
| Shaking & Incubation | |
|
Incubation Location : 6 independent control board positions, compatible with dilution board Incubation Location |
6 independent control board positions, compatible with dilution board |
|
Shaking Grade : 0–2 degree Shaking Grade |
0–2 degree |
|
Shaking Time : 0–250 sec., increasing step 1 sec. Shaking Time |
0–250 sec., increasing step 1 sec. |
|
Incubation Temperature Range : 30–75°C Incubation Temperature Range |
30–75°C |
|
Temperature Increment : 0.1°C Temperature Increment |
0.1°C |
|
Incubation Time : 0–250 min. Incubation Time |
0–250 min. |
| Washing Module | |
|
Washing Head Channel : Double row with 16 channels Washing Head Channel |
Double row with 16 channels |
|
Injection Grade : 4 grades: low, medium, high and strong Injection Grade |
4 grades: low, medium, high and strong |
|
Soaking Time : 0–250 sec. Soaking Time |
0–250 sec. |
|
Cleaning Frequency : 1–10 washes Cleaning Frequency |
1–10 washes |
|
Cleaning Row Number : 1–12 Cleaning Row Number |
1–12 |
|
Residual Fluid Volume : <1 μL/well Residual Fluid Volume |
<1 μL/well |
| Optional Microplate Reader | |
|
Wavelength : 340–750 nm Wavelength |
340–750 nm |
|
Accuracy : ±1% Accuracy |
±1% |
|
Resolution : 0.001 OD Resolution |
0.001 OD |
|
Plate : 96-well plate Plate |
96-well plate |
|
Absorbance Mode : Fluorescence optional Absorbance Mode |
Fluorescence optional |
|
Light Source : LED/Halogen Light Source |
LED/Halogen |
|
Integrated Shaker : Available Integrated Shaker |
Available |
|
Software : Standard curve & quantification Software |
Standard curve & quantification |
|
Programmable Cycles : 1–10 Programmable Cycles |
1–10 |
|
Dispensing Accuracy : ≤5% Dispensing Accuracy |
≤5% |
|
Washer Residual : ≤2 μL/well Washer Residual |
≤2 μL/well |
|
Plate Compatibility : Standard plates Plate Compatibility |
Standard plates |