ISO & CE Certified • Global Supply Chain • Comprehensive Warranty
WhatsApp Us!
Request Quote!
0
UV-Vis-NIR Spectrophotometer NSP-05
NSP-05

UV-Vis-NIR Spectrophotometer NSP-05

Labotemp UV-Vis-NIR Spectrophotometer NSP-05 is a double-beam analytical instrument designed for spectral measurement across ultraviolet, visible and near-infrared regions. With a wavelength range of 190–3200 nm in transmission and specular reflectance modes and 250–2500 nm in integrating sphere mode, this system supports analysis of optical properties in glass, films, materials and other suitable samples. Its Czerny-Turner optical system, deuterium and tungsten light sources, and PMT and PbS detectors support multiple spectral measurement applications.

Featuring automatic calibration, computer-based control and integrated spectral analysis software, NSP-05 provides transmission, absorbance, reflectivity and energy measurement modes. Adjustable spectral bandwidth and sampling intervals support different testing requirements, while dedicated accessories accommodate integrating sphere, powder sample, transmission, thin-film, liquid transmission and reflection measurements. USB 2.0 connectivity enables computer communication, data acquisition and processing for laboratory research and material testing.

Why Choose Labotemp UV-Vis-NIR Spectrophotometer NSP-05?

✓Broad Wavelength Coverage: Spectral measurement from 190 to 3200 nm in specified measurement modes.
✓Double-Beam Optical System: Supports spectral measurement across UV, visible and near-infrared regions.
✓Flexible Sample Testing: Compatible optional accessories for different sample measurement configurations.

$19074
Datasheet

Specifications UV-Vis-NIR Spectrophotometer NSP-05

General Information

Product Type : UV-Vis-NIR Spectrophotometer

Product Type
UV-Vis-NIR Spectrophotometer

Model : NSP-05

Model
NSP-05

Optical System : Double Beam

Optical System
Double Beam

Optical Design : Czerny-Turner

Optical Design
Czerny-Turner

Light Sources : Deuterium Lamp, Tungsten Lamp

Light Sources
Deuterium Lamp, Tungsten Lamp

Detectors : PMT, PbS

Detectors
PMT, PbS

Operating Modes : Transmission, Absorbance, Reflectivity, Energy

Operating Modes
Transmission, Absorbance, Reflectivity, Energy
Wavelength Performance

Wavelength Range: Transmission and Specular Reflectance : 190–3200 nm

Wavelength Range: Transmission and Specular Reflectance
190–3200 nm

Wavelength Range: Integrating Sphere : 250–2500 nm

Wavelength Range: Integrating Sphere
250–2500 nm

Wavelength Accuracy: UV-Vis : ±0.5 nm

Wavelength Accuracy: UV-Vis
±0.5 nm

Wavelength Accuracy: NIR : ±0.4 nm

Wavelength Accuracy: NIR
±0.4 nm

Wavelength Repeatability: UV-Vis : ≤0.2 nm

Wavelength Repeatability: UV-Vis
≤0.2 nm

Wavelength Repeatability: NIR : ≤1 nm

Wavelength Repeatability: NIR
≤1 nm

Spectral Bandwidth: UV-Vis : 0.1–7 nm

Spectral Bandwidth: UV-Vis
0.1–7 nm

Spectral Bandwidth: NIR : 0.8–20 nm

Spectral Bandwidth: NIR
0.8–20 nm

Available Sampling Intervals : 0.1, 0.2, 0.5, 1, 1.5, 2, 5 and 10 nm

Available Sampling Intervals
0.1, 0.2, 0.5, 1, 1.5, 2, 5 and 10 nm
Photometric Performance

Photometric Range : 0–3 A

Photometric Range
0–3 A

Photometric Accuracy : ±0.3%T (0–100%T)

Photometric Accuracy
±0.3%T (0–100%T)

Photometric Repeatability : ≤0.2%T

Photometric Repeatability
≤0.2%T

Stray Light : ≤0.2%T at 360 nm and 420 nm

Stray Light
≤0.2%T at 360 nm and 420 nm

Stability : ±0.002 A/h at 500 nm, 0 A

Stability
±0.002 A/h at 500 nm, 0 A

Baseline Flatness: 190–3200 nm : ±1%T after 30 minutes warm-up

Baseline Flatness: 190–3200 nm
±1%T after 30 minutes warm-up

Baseline Flatness: 200–2500 nm : ±0.5%T after 30 minutes warm-up

Baseline Flatness: 200–2500 nm
±0.5%T after 30 minutes warm-up
Optical Components

Diffraction Grating: UV-Vis : 1200 lines/mm

Diffraction Grating: UV-Vis
1200 lines/mm

Diffraction Grating: NIR : 300 lines/mm

Diffraction Grating: NIR
300 lines/mm
Software and Connectivity

Computer Interface : USB 2.0

Computer Interface
USB 2.0

Software : Operational Software

Software
Operational Software

Automatic Calibration : Supported

Automatic Calibration
Supported

Data Acquisition : Automatic

Data Acquisition
Automatic

Data Processing : Supported

Data Processing
Supported

Data Import and Export : Supported

Data Import and Export
Supported

Compatible Operating Systems : Windows XP, Windows 7

Compatible Operating Systems
Windows XP, Windows 7
Electrical Requirements

Power Supply : AC 110/220 V

Power Supply
AC 110/220 V

Frequency : 50/60 Hz

Frequency
50/60 Hz
Dimensions and Weight

External Dimensions (W × D × H) : 760 × 605 × 300 mm

External Dimensions (W × D × H)
760 × 605 × 300 mm

Package Dimensions (W × D × H) : 870 × 750 × 505 mm

Package Dimensions (W × D × H)
870 × 750 × 505 mm

Net Weight : 48 kg

Net Weight
48 kg

Gross Weight : 60 kg

Gross Weight
60 kg

Features UV-Vis-NIR Spectrophotometer NSP-05

  • PMT and PbS Detectors ➤ PMT and PbS Detectors
  • Double-Beam Optical Configuration ➤ Double-Beam Optical Configuration
  • Deuterium and Tungsten Light Sources ➤ Deuterium and Tungsten Light Sources
  • PMT and PbS Detectors ➤ PMT and PbS Detectors
  • Czerny-Turner Monochromator ➤ Czerny-Turner Monochromator
  • Diffraction Grating Optical System ➤ Diffraction Grating Optical System
  • Automatic Calibration on Startup ➤ Automatic Calibration on Startup
  • Computer-Based Instrument Control ➤ Computer-Based Instrument Control
  • Transmission Measurement ➤ Transmission Measurement
  • Absorbance Measurement ➤ Absorbance Measurement
  • Reflectivity Measurement ➤ Reflectivity Measurement
  • Energy Measurement ➤ Energy Measurement
  • Automatic Data Acquisition ➤ Automatic Data Acquisition
  • Spectral Data Processing ➤ Spectral Data Processing
  • Real-Time Sample Measurement ➤ Real-Time Sample Measurement
  • Data Import and Export ➤ Data Import and Export
  • USB 2.0 Interface ➤ USB 2.0 Interface

Applications UV-Vis-NIR Spectrophotometer NSP-05

  • Glass Testing: Spectral analysis of glass transmission and reflectance properties Glass Testing
    Spectral analysis of glass transmission and reflectance properties
  • Energy Efficiency Testing: Measurement of optical properties relevant to energy-efficient materials and glazing Energy Efficiency Testing
    Measurement of optical properties relevant to energy-efficient materials and glazing
  • Construction Material Inspection: Optical testing for construction engineering quality assessment Construction Material Inspection
    Optical testing for construction engineering quality assessment
  • Automotive Glass Testing: Spectral measurement of suitable automotive safety glass samples Automotive Glass Testing
    Spectral measurement of suitable automotive safety glass samples
  • Materials Science Research: Spectral characterization of materials across ultraviolet, visible and near-infrared regions Materials Science Research
    Spectral characterization of materials across ultraviolet, visible and near-infrared regions
  • Scientific Research: Optical measurement and spectral analysis in research laboratories Scientific Research
    Optical measurement and spectral analysis in research laboratories
  • Higher Education: Spectroscopy experiments and material analysis in academic laboratories Higher Education
    Spectroscopy experiments and material analysis in academic laboratories

Optional Accessories

  • Integrating Sphere Accessory (60/100 mm) ➤ Integrating Sphere Accessory (60/100 mm)
  • Powder Sample Accessory ➤ Powder Sample Accessory
  • Transmission Accessory ➤ Transmission Accessory
  • Thin Film Testing Accessory ➤ Thin Film Testing Accessory
  • Liquid Transmission Accessory ➤ Liquid Transmission Accessory
  • Reflection Accessory ➤ Reflection Accessory