Labotemp Hydrogen Tube Furnace 1200°C FMT 19 delivers controlled high temperature processing up to 1200°C, with a 440 mm single hot zone, OD 80 × ID 72 mm tube, and ±1°C temperature accuracy. Designed for controlled atmosphere heat treatment, the furnace supports N₂, Ar, and H₂ gases with a gas flow range of 60 to 600 mL/min. Its HRE heating wire, Type N thermocouple, programmable PID controller, and alumina ceramic fiber chamber provide controlled heating conditions for demanding thermal processing applications.
FMT 19 incorporates an H₂ detection device with gas interlock and a PLC-controlled ignition system for hydrogen atmosphere operation. The furnace can operate at 1100°C continuously and reach 1200°C for processes up to 2 hours, while the integrated mechanical vacuum pump provides a pumping speed of 2 L/s. The system also includes air cooling, single point temperature measurement, over temperature protection, power failure recovery, and microprocessor based self tuning PID control. Controlled atmosphere tube furnaces are commonly used where materials require processing under gases such as hydrogen or inert gases rather than ordinary air.
Why Choose Labotemp Hydrogen Tube Furnace 1200°C FMT 19?
✓ 1200°C Maximum Temperature: Supports high temperature processing up to 1200°C for controlled thermal treatment.
✓ Controlled Gas Atmosphere: Supports N₂, Ar, and H₂ atmospheres with adjustable gas flow from 60 to 600 mL/min.
✓ Programmable Temperature Control: 50 segment PID controller with automatic tuning supports controlled heating processes.
| Furnace Performance | |
|
Furnace Type : Horizontal Hydrogen Tube Furnace Furnace Type |
Horizontal Hydrogen Tube Furnace |
|
Maximum Temperature : 1200°C, ≤2 hours Maximum Temperature |
1200°C, ≤2 hours |
|
Continuous Working Temperature : 1100°C Continuous Working Temperature |
1100°C |
|
Hot Zone Length : 440 mm Hot Zone Length |
440 mm |
|
Temperature Accuracy : ±1°C Temperature Accuracy |
±1°C |
|
Temperature Uniformity : ±5°C Temperature Uniformity |
±5°C |
|
Heating Rate : ≤25°C/min Heating Rate |
≤25°C/min |
|
Heating Element : HRE Heating Wire Heating Element |
HRE Heating Wire |
|
Cooling Method : Air Cooling Cooling Method |
Air Cooling |
| Tube and Chamber | |
|
Tube Size : OD 80 × ID 72 mm Tube Size |
OD 80 × ID 72 mm |
|
Furnace Tube : Quartz Tube with SS304 Water Cooling Sealing Flange and Silicone O Rings Furnace Tube |
Quartz Tube with SS304 Water Cooling Sealing Flange and Silicone O Rings |
|
Chamber Material : Alumina 1500 Grade Ceramic Fiber Chamber Material |
Alumina 1500 Grade Ceramic Fiber |
|
Furnace Door : Split Able Furnace Door |
Split Able |
|
Temperature Measurement : Single Point Measurement Temperature Measurement |
Single Point Measurement |
| Temperature Control | |
|
Temperature Controller : 50 Segment Programmable PID Controller Temperature Controller |
50 Segment Programmable PID Controller |
|
Control Function : PID Automatic Control and Auto Tune Control Function |
PID Automatic Control and Auto Tune |
|
Temperature Monitoring : At Center of Chamber Temperature Monitoring |
At Center of Chamber |
|
Overtemperature Protection : Available Overtemperature Protection |
Available |
|
Power Failure Protection : Available Power Failure Protection |
Available |
|
Control System : Microprocessor Based Control System |
Microprocessor Based |
| Atmosphere and Gas System | |
|
Available Process Gases : N₂, Ar, H₂ Available Process Gases |
N₂, Ar, H₂ |
|
Gas Flow Range : 60 to 600 mL/min Gas Flow Range |
60 to 600 mL/min |
|
Flow Measurement : Dual Float Flowmeter Flow Measurement |
Dual Float Flowmeter |
|
Hydrogen Detection : H₂ Detection Device Hydrogen Detection |
H₂ Detection Device |
|
Hydrogen Safety : Gas Interlock Hydrogen Safety |
Gas Interlock |
|
Ignition System : PLC Controlled Ignition Device Ignition System |
PLC Controlled Ignition Device |
| Vacuum System | |
|
Vacuum Pump Type : Mechanical Pump Vacuum Pump Type |
Mechanical Pump |
|
Pumping Speed : 2 L/s Pumping Speed |
2 L/s |
|
Vacuum Operation : Supported Vacuum Operation |
Supported |
| Electrical and Operating Conditions | |
|
Power Supply : 220 V, 50 Hz, Single Phase Power Supply |
220 V, 50 Hz, Single Phase |
|
Ambient Temperature : 0 to 50°C Ambient Temperature |
0 to 50°C |
|
Relative Humidity : ≤90% Relative Humidity |
≤90% |
| Packaging details | |
|
Gross Weight : 250kg Gross Weight |
250kg |
|
Packaging Dimensions : 1500x800x 800mm Packaging Dimensions |
1500x800x 800mm |